| Werkstoff Gehäuse | PA-reinforced | ||
| LED display, product-specific | M: Modify, parameterisation PL: Load supply PS: Electronics supply, sensor supply SF: System fault | ||
| Protokoll | ETHERNET POWERLINK V2 | ||
| Max. address volume, outputs | 64 Byte | ||
| Umgebungstemperatur | -5 °C ... 50 °C | ||
| Lagertemperatur | -20 °C ... 70 °C | ||
| Nennbetriebsspannung DC | 24 V | ||
| Betriebsspannungsbereich DC | 18 V ... 30 V | ||
| Operator controls | DIL switch | ||
| Verpolungsschutz | For operating voltage | ||
| Parameterisation | Diagnostic behaviour Fail-safe response Forcing of channels Signal setup System parameter | ||
| Field bus interface | 2x socket, M12x1, 4-pin, D-coded |
| Werkstoff-Hinweis | RoHS-compliant | ||
| LED display, bus-specific | BE: POWERLINK error BS: Powerlink status L/A1: Link/activity port 1 L/A2: Link/activity port 2 | ||
| Max. address volume, inputs | 64 Byte | ||
| Produktgewicht | 125 g | ||
| Schutzart | IP65 IP67 | ||
| Korrosionsbeständigkeitsklasse KBK | 1 - Low corrosion stress | ||
| Intern power consumption nominal operating voltage | Typically 100 mA | ||
| Baud rate | 100 Mbit/s | ||
| Zusatzfunktionen | Acyclic data access via SDO Asynchronous data access via Ethernet - IP addressing via DHCP, DIL switch or operator unit Integrated hub Channel-oriented diagnostics via fieldbus Start-up parameterisation in plain text via fieldbus System status can be mapped using process data Additional diagnostic interface for operator units | ||
| Configuration support | XDC-file XDD-file | ||
| Device-specific diagnostics | Channel-oriented and module-oriented diagnostics Undervoltage of modules Diagnostic memory | ||
| Abmessungen B x L x H | (incl. interlinking block) 50 x 107 x 50 mm |