| switching capacity (auxiliary contacts, pilot duty) | p300, dc operated (ul/csa) a600, ac operated (ul/csa) |
||
| Baureihe | reversing starter | ||
| rated control supply voltage (us) at ac, 60 hz - max | 0 v | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| rated conditional short-circuit current (iq), type 2, 230 v | 0 a | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| rated impulse withstand voltage (uimp) | 6000 v ac | ||
| rated control supply voltage (us) at ac, 60 hz - min | 0 v | ||
| Schutzart | ip20 nema other |
||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| rated conditional short-circuit current (iq), type 2, 380 v, 400 v, 415 v | 50 a | ||
| rated operational current (ie) | 11.3 a | ||
| equipment heat dissipation, current-dependent pvid | 9.9 w | ||
| product length/depth | 185 mm | ||
| overload release current setting - min | 8 a | ||
| voltage type | dc | ||
| 10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| class | class 10 a | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| power consumption (sealing) at dc | 4.5 w | ||
| electrical connection type of main circuit | screw connection | ||
| connection to smartwire-dt | no | ||
| ambient operating temperature - max | 55 °c | ||
| coordination class (iec 60947-4-3) | class 1 | ||
| coordination type | 1 | ||
| fitted with: | short-circuit release | ||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| rated power at 575 v, 60 hz, 3-phase | 0 kw | ||
| mounting method | rail mounting possible | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| rated conditional short-circuit current, type 1, 480 y/277 v | 0 a | ||
| rated operational power at ac-3, 380/400 v, 50 hz | 5.5 kw | ||
| rated operational current for specified heat dissipation (in) | 12 a | ||
| Produktgewicht | 1.04 kg |
| altitude | max. 2000 m | ||
| rated operational current (ie) at ac-3, 380 v, 400 v, 415 v | 12 a | ||
| short-circuit release (irm) - max | 186 a | ||
| 10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
| Typ | reversing starter | ||
| functions | temperature compensated overload protection | ||
| Anschluss | screw terminals | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| Verschmutzungsgrad | 3 | ||
| Overvoltage category | iii | ||
| overload release current setting - max | 12 a | ||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| suitable for | also motors with efficiency class ie3 | ||
| heat dissipation capacity pdiss | 0 w | ||
| product height | 95 mm | ||
| ean | 4015082832032 | ||
| switching capacity (auxiliary contacts, general use) | 15 a, 600 v ac, (ul/csa) 1 a, 250 v dc, (ul/csa) |
||
| heat dissipation per pole, current-dependent pvid | 3.3 w | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| ambient operating temperature - min | -25 °c | ||
| rated control supply voltage (us) at dc - max | 24 v | ||
| electrical connection type for auxiliary- and control-current circuit | screw connection | ||
| static heat dissipation, non-current-dependent pvs | 2.6 w | ||
| rated operational power at ac-3, 220/230 v, 50 hz | 3 kw | ||
| rated conditional short-circuit current, type 1, 600 y/347 v | 0 a | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| rated control supply voltage (us) at ac, 50 hz - max | 0 v | ||
| rated control supply voltage (us) at dc - min | 24 v | ||
| rated power at 460 v, 60 hz, 3-phase | 0 kw | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| rated control supply voltage (us) at ac, 50 hz - min | 0 v | ||
| rated operational voltage | 230 - 415 v ac | ||
| 10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| certifications | csa-c22.2 no. 14-10 csa file no.: 012528 ul ul 508 (on request) iec/en 60947-4-1 csa class no.: 3211-24 ul60947-4-1a ul category control no.: nkjh csa-c22.2 no. 14 (on request) ul file no.: e123500 csa ce |
||
| product width | 90 mm |