REXROTH WE
5224 Produkte
Entdecken Sie alle verfügbaren Konfigurationen für die Produktserie REXROTH WE – WE, Directional valve WE, Directional valve. Finden Sie das passende Produkt durch Filtern mit Ausführung, Haupthäfen, Baureihe, Baugröße, Symbole, Baureihe, Feder-Rückstellung, Elektrische Spannungen, Solenoidtyp, Explosionsschutz, Gleichspannung, Handhilfsbetätigung, Korrosionsbeständigkeit, Elektrischer Anschluss, Überwachung der Spulenposition, Erhöhung der Schaltzeit, Spannlänge, Drossel-Einsatz, Steuerungsspulenspiel, Dichtungsmaterial, Zulassung, Ortungshon, Genehmigungen und Power consumption.
WE Typcodes
| Serie | Katalognummernformat | Beschreibung |
|---|---|---|
| WE | -WE-6- -6X-E- - | WE |
| WE | -WE-10- -5X-E- - - | WE |
| WE | -WE-6- -6X-E- | Directional valve WE |
| WE | -WE-6- -7X-H- -N9 | Directional valve WE |
| WE | -WE-6- -6X-E- -XE-Z2 | Directional valve WE |
| WE | -WE-6- -6X-B- -XD-Z2 | WE |
| WE | -WE-6- -5X-B- -N-VP1-Z2 | Directional valve |
| WE | 5- -WE-10- -5X-E- - - | Directional valve |
| WE | -WE-6- -6X-E-G24-N9-XN | Directional valve WE |
| WE | -WE-6- -5X-B- -N- - | Directional valve WE |
| WE | -WE-6- -6X-E- -VE1-Z2 | Directional valve |
| Show more records | ||
| 001 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 002 | Series |
| WE | WE |
| 003 | Size |
| 6 | 6 |
| 004 | Symbols |
| A | A |
| C | C |
| D | D |
| D73 | D73 |
| E67 | E67 |
| E | E |
| EA | EA |
| EB | EB |
| G | G |
| GA | GA |
| H | H |
| HA | HA |
| HB | HB |
| J | J |
| J73 | J73 |
| J73A | J73A |
| JA | JA |
| L | L |
| LA | LA |
| LB | LB |
| M | M |
| T | T |
| TA | TA |
| W | W |
| W73 | W73 |
| Y | Y |
| B | B |
| B9 | B9 |
| H73B | H73B |
| JB | JB |
| MA | MA |
| MB | MB |
| R | R |
| RB | RB |
| U | U |
| UA | UA |
| V | V |
| WB | WB |
| A9 | A9 |
| D46 | D46 |
| Y11 | Y11 |
| D6 | D6 |
| C73 | C73 |
| E73 | E73 |
| FB | FB |
| Q | Q |
| WA | WA |
| Y2 | Y2 |
| G73A | G73A |
| GB | GB |
| L42B | L42B |
| PA | PA |
| Q23 | Q23 |
| X34 | X34 |
| D25 | D25 |
| D9 | D9 |
| FA | FA |
| PB | PB |
| W73B | W73B |
| X62A | X62A |
| G73 | G73 |
| UB | UB |
| VA | VA |
| VB | VB |
| H2A | H2A |
| H73A | H73A |
| J19A | J19A |
| QB | QB |
| D19 | D19 |
| E13 | E13 |
| H19 | H19 |
| QA | QA |
| X41 | X41 |
| H73 | H73 |
| P | P |
| X7 | X7 |
| A73 | A73 |
| J19B | J19B |
| X5A | X5A |
| J73B | J73B |
| X26A | X26A |
| E163 | E163 |
| F | F |
| U10B | U10B |
| X48B | X48B |
| X12 | X12 |
| L37B | L37B |
| X4B | X4B |
| B73 | B73 |
| F19B | F19B |
| X6 | X6 |
| E73A | E73A |
| B4 | B4 |
| G11A | G11A |
| J2 | J2 |
| X191 | X191 |
| E34A | E34A |
| J25 | J25 |
| TB | TB |
| D20 | D20 |
| G3 | G3 |
| J5B | J5B |
| J50B | J50B |
| U24A | U24A |
| J5 | J5 |
| M73A | M73A |
| X47A | X47A |
| W73A | W73A |
| Y73 | Y73 |
| F19 | F19 |
| Y13 | Y13 |
| X38 | X38 |
| U67B | U67B |
| U73A | U73A |
| Y9 | Y9 |
| 005 | Component series |
| 6X | 60 ... 69: unchanged installation and connection dimensions |
| 006 | Spring return |
| With spring return | |
| O | Without spring return |
| OF | Without spring return with detent |
| 007 | Solenoid |
| E | High-power wet-pin solenoid with detachable coil |
| 008 | Electrical voltages |
| G12 | 12V |
| G24 | 24V |
| G26 | 62V |
| G48 | 48V |
| G96 | 96V, 100V 50/60 Hz, 110V 50/60 Hz |
| G110 | 110V, 120V 60Hz |
| G125 | 125V |
| G180 | 200V 50Hz |
| G205 | 205V, 230V 50/60Hz |
| G220 | 220V |
| W100 | 100V 50/60 Hz |
| W110 | 110V 50/60 Hz, 120V 60HZ |
| W200 | 200V 50Hz/60Hz |
| W230 | 230V, 50/60Hz |
| W100R | 100V, 50/60Hz |
| W110R | 110V, 50/60Hz |
| W120 | 110V 50Hz, 120V 60Hz |
| W120R | 120V 60Hz |
| W200R | 200V 50/60Hz |
| W230R | 230V 50/60Hz |
| 009 | Manual override |
|---|---|
| Without manual override | |
| N | With manual override |
| N2 | With manual override 'mushroom button' (small) |
| N4 | With lockable manual override 'mushroom button' (small) |
| N5 | With lockable manual override 'mushroom button' (large) |
| N6 | With manual override 'mushroom button' (large), not lockable |
| N7 | With lockable manual override 'nut' |
| N8 | With concealed manual override and protective cap |
| N9 | With concealed manual override (standard) |
| 010 | Corrosion resistance |
| None (valve housing primed) | |
| J3 | Improved corrosion protection (240 h salt spray test according to EN ISO 9227) |
| J5 | High corrosion protection (720 h salt spray test according to EN ISO 9227) |
| 011 | Electrical connection |
| K4 | Standard |
| K4K | With potted-in plug base and sealing element |
| K40 | Connector 2-pole, DT04-2PA (Deutsch type) |
| K72L | Pin assignment according to DESINA |
| K73L | Standard |
| C4 | Connector parallel to the valve axis |
| C4Z | Connector radial to the valve axis |
| DL | With indicator light |
| DL1 | With indicator light and interference protection circuit |
| DAL | With indicator light |
| DAL1 | With indicator light and interference protection circuit |
| DK6L | With indicator light |
| DK6L1 | With indicator light and interference protection circuit |
| DK23L | With indicator light, 3-pole |
| DK25L | With indicator light, 5-pole |
| DK24L | With indicator light |
| DK24L1 | With indicator light and interference protection circuit |
| DK35L | With indicator light and interference protection circuit |
| DJL | With indicator light and interference protection circuit |
| DK25L | With indicator light, 5-pole |
| 012 | Spool position monitoring |
| Without position switch | |
| QMAG24 | Monitored spool position 'a |
| QMBG24 | Monitored spool position 'b' |
| QM0G24 | Monitored rest position |
| QR0G24S | Monitored rest position |
| QRABG24E | Monitored spool position 'a' and 'b' |
| QSAG24W | Monitored spool position 'a' |
| QSBG24W | Monitored spool position 'b' |
| QS0G24W | Monitored spool position '0' |
| QS0AG24W | Monitored spool position '0' and 'a' |
| QS0BG24W | Monitored spool position '0' and 'b' |
| QSABG24W | Monitored spool position '0' and 'a' |
| 013 | Switching time increase |
| Without switching time increase | |
| A12 | With switching time increase (only with direct voltage and only with version 'N9' and symbol '73') |
| 014 | Throttle insert |
| Without throttle insert (standard) | |
| B06 | With throttle insert |
| B08 | With throttle insert |
| B10 | With throttle insert |
| B12 | With throttle insert |
| B15 | With throttle insert |
| B20 | With throttle insert |
| B25 | With throttle insert |
| B30 | With throttle insert |
| B40 | With throttle insert |
| H06 | With throttle insert |
| H08 | With throttle insert |
| H10 | With throttle insert |
| H12 | With throttle insert |
| H15 | With throttle insert |
| H20 | With throttle insert |
| H25 | With throttle insert |
| H30 | With throttle insert |
| H40 | With throttle insert |
| R06 | With throttle insert |
| R08 | With throttle insert |
| R10 | With throttle insert |
| R12 | With throttle insert |
| R15 | With throttle insert |
| R20 | With throttle insert |
| R25 | With throttle insert |
| R30 | With throttle insert |
| R40 | With throttle insert |
| N06 | With throttle insert |
| N08 | With throttle insert |
| N10 | With throttle insert |
| N12 | With throttle insert |
| N15 | With throttle insert |
| N20 | With throttle insert |
| N25 | With throttle insert |
| N30 | With throttle insert |
| N40 | With throttle insert |
| X06 | With throttle insert |
| X08 | With throttle insert |
| X10 | With throttle insert |
| X12 | With throttle insert |
| X15 | With throttle insert |
| X20 | With throttle insert |
| X25 | With throttle insert |
| X30 | With throttle insert |
| X40 | With throttle insert |
| 015 | Clamping length |
| 42 mm [1.65 inch] (standard) | |
| Z | 22 mm [0.87 inch] |
| 016 | Control spool play |
| Standard (recommended) | |
| T06 | Minimum (selection for reduced leakage values; higher oil cleanliness required) |
| T12 | Increased (selection with high temperature difference hydraulic fluid/environment; leads to higher internal leakage values) |
| 017 | Seal material |
| NBR seals | |
| V | FKM seals |
| MH | Recommended for operation with HFC hydraulic fluids together with high temperatures |
| MT | Low-temperature version (only with version Without manual override) |
| 018 | Approval |
| Standard | |
| UR | Solenoid coil as approved component with UR marking according to UL 906, edition 1982 |
| CSA | Approval according to CSA C22.2 No. 139-1982 |
| AN | Porting pattern according to ANSI B93.9 |
| 019 | Locating hone |
| Without locating hole | |
| 62 | With locating hole and locking pin ISO 8752-3x8-St |
| 020 | Power consumption |
| Standard | |
| SO407 | With reduced electric power consumption (only versions 'G24' as well as 'K4', 'DL' and 'DKL') |
| 001 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 002 | Series |
| WE | WE |
| 003 | Size |
| 10 | 10 |
| 004 | Symbols |
| A | A |
| C | C |
| D | D |
| GA | GA |
| H | H |
| HA | HA |
| J2B | J2B |
| J32 | J32 |
| J | J |
| E | E |
| E73 | E73 |
| G | G |
| H73 | H73 |
| J2 | J2 |
| J73 | J73 |
| JB | JB |
| LB | LB |
| M | M |
| MA | MA |
| Q | Q |
| R | R |
| R6 | R6 |
| U10B | U10B |
| W | W |
| Y11 | Y11 |
| Y | Y |
| Y73 | Y73 |
| E34 | E34 |
| EB | EB |
| D73 | D73 |
| F | F |
| G73 | G73 |
| P | P |
| B | B |
| B1 | B1 |
| E19 | E19 |
| E67 | E67 |
| EA | EA |
| L | L |
| MB | MB |
| UA | UA |
| E73B | E73B |
| G73A | G73A |
| X10B | X10B |
| X185 | X185 |
| T | T |
| H73A | H73A |
| JA | JA |
| HB | HB |
| R73 | R73 |
| RB | RB |
| U | U |
| J73B | J73B |
| A73 | A73 |
| A4 | A4 |
| B9 | B9 |
| E13 | E13 |
| GB | GB |
| X5A | X5A |
| X7 | X7 |
| PA | PA |
| X34 | X34 |
| P19 | P19 |
| G3 | G3 |
| J19B | J19B |
| J73A | J73A |
| FA | FA |
| UB | UB |
| V | V |
| VA | VA |
| E73A | E73A |
| VB | VB |
| J5 | J5 |
| X6 | X6 |
| Q6 | Q6 |
| H73B | H73B |
| J5A | J5A |
| R73B | R73B |
| X4A | X4A |
| J5B | J5B |
| L73 | L73 |
| H2B | H2B |
| QA | QA |
| QB | QB |
| TB | TB |
| X10 | X10 |
| D28 | D28 |
| TA | TA |
| B73 | B73 |
| D55 | D55 |
| E36 | E36 |
| LA | LA |
| U12 | U12 |
| Y2 | Y2 |
| 005 | Component series |
| 5X | Component series 50 … 59 (50 … 59: unchanged installation and connection dimensions) |
| 006 | Spring return |
| With spring return | |
| D | With reinforced compression spring (for quick switching off) |
| O | Without spring return |
| OF | Without spring return with detent |
| 007 | Solenoid |
| E | High-power wet-pin solenoid with detachable coil |
| 008 | Electrical voltages |
| G12 | 12V |
| G24 | 24V |
| G26 | 62V |
| G48 | 48V |
| G96 | 96V, 100V 50/60 Hz, 110V 50/60 Hz |
| G110 | 110V, 120V 60Hz |
| G125 | 125V |
| G180 | 200V 50Hz |
| G205 | 205V, 230V 50/60Hz |
| G220 | 220V |
| W100 | 100V 50/60 Hz |
| W110 | 110V 50/60 Hz, 120V 60HZ |
| W200 | 200V 50Hz/60Hz |
| W230 | 230V, 50/60Hz |
| W100R | 100V, 50/60Hz |
| W110R | 110V, 50/60Hz |
| W120 | 110V 50Hz, 120V 60Hz |
| W120R | 120V 60Hz |
| W200R | 200V 50/60Hz |
| W230R | 230V 50/60Hz |
| 009 | Manual override |
|---|---|
| Without manual override | |
| N5 | With lockable manual override 'mushroom button' (large) |
| N6 | With manual override 'mushroom button' (large), not lockable |
| N8 | With concealed manual override and protective cap |
| N9 | With concealed manual override (standard) |
| 010 | Corrosion resistance |
| None (valve housing primed) | |
| J3 | Improved corrosion protection (240 h salt spray test according to EN ISO 9227) |
| 011 | Electrical connection |
| K4 | Standard |
| K4K | With potted-in plug base and sealing element |
| K40 | Connector 2-pole, DT04-2PA (Deutsch type) |
| K72L | Pin assignment according to DESINA |
| K73L | Standard |
| C4 | Connector parallel to the valve axis |
| C4Z | Connector radial to the valve axis |
| DL | With indicator light |
| DL1 | With indicator light and interference protection circuit |
| DAL | With indicator light |
| DAL1 | With indicator light and interference protection circuit |
| DK6L | With indicator light |
| DK6L1 | With indicator light and interference protection circuit |
| DK23L | With indicator light, 3-pole |
| DK25L | With indicator light, 5-pole |
| DK24L | With indicator light |
| DK24L1 | With indicator light and interference protection circuit |
| DK35L | With indicator light and interference protection circuit |
| DJL | With indicator light and interference protection circuit |
| DK25L | With indicator light, 5-pole |
| 012 | Switching time increase |
| Without switching time increase | |
| A12 | With switching time increase (only with direct voltage and only with version 'N9' and symbol '73') |
| 013 | Throttle insert |
| Without throttle insert (standard) | |
| B06 | With throttle insert |
| B08 | With throttle insert |
| B10 | With throttle insert |
| B12 | With throttle insert |
| B15 | With throttle insert |
| B20 | With throttle insert |
| B25 | With throttle insert |
| B30 | With throttle insert |
| B40 | With throttle insert |
| H06 | With throttle insert |
| H08 | With throttle insert |
| H10 | With throttle insert |
| H12 | With throttle insert |
| H15 | With throttle insert |
| H20 | With throttle insert |
| H25 | With throttle insert |
| H30 | With throttle insert |
| H40 | With throttle insert |
| R06 | With throttle insert |
| R08 | With throttle insert |
| R10 | With throttle insert |
| R12 | With throttle insert |
| R15 | With throttle insert |
| R20 | With throttle insert |
| R25 | With throttle insert |
| R30 | With throttle insert |
| R40 | With throttle insert |
| N06 | With throttle insert |
| N08 | With throttle insert |
| N10 | With throttle insert |
| N12 | With throttle insert |
| N15 | With throttle insert |
| N20 | With throttle insert |
| N25 | With throttle insert |
| N30 | With throttle insert |
| N40 | With throttle insert |
| X06 | With throttle insert |
| X08 | With throttle insert |
| X10 | With throttle insert |
| X12 | With throttle insert |
| X15 | With throttle insert |
| X20 | With throttle insert |
| X25 | With throttle insert |
| X30 | With throttle insert |
| X40 | With throttle insert |
| 014 | Control spool play |
| Standard (recommended) | |
| T06 | Minimum (selection for reduced leakage values; higher oil cleanliness required) |
| T12 | Increased (selection with high temperature difference hydraulic fluid/environment; leads to higher internal leakage values) |
| 015 | Seal material |
| M | NBR seals |
| V | FKM seals |
| MH | Recommended for operation with HFC hydraulic fluids together with high temperatures |
| MT | Low-temperature version (only with version Without manual override) |
| 016 | Approval |
| Standard | |
| CSA | Approval according to CSA C22.2 No. 139-1982 |
| AN | Porting pattern according to ANSI B93.9 |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | Directional valve WE |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| B9 | B9 |
| J | J |
| D | D |
| G | G |
| JA | JA |
| A | A |
| E | E |
| MB | MB |
| EB | EB |
| HA | HA |
| L | L |
| F | F |
| EA | EA |
| Y | Y |
| M | M |
| B | B |
| 05 | Component series |
| 6X | Component series 60 … 69 (60 … 69: Unchanged installation and connection dimensions) |
| 06 | Spring return |
| With spring return | |
| O | Without spring return |
| OF | Without spring return with detent |
| 07 | Solenoid type |
|---|---|
| E | High-power solenoid, wet (wet-pin) |
| 08 | Electrical voltages |
| G24 | Direct voltage 24 V |
| G48 | Direct voltage 48 V |
| G110 | Direct voltage 110 V |
| 09 | Manual override |
| Without manual override | |
| N | With manual override |
| 10 | Explosion protection |
| XE | Increased safety |
| 11 | Electrical connection |
| Z2 | Solenoid with terminal box and cable gland |
| 12 | Throttle insert |
| Without throttle insert | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |
| 001 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 002 | Series |
| WE | Directional valve WE |
| 003 | Size |
| 6 | Size 6 |
| 004 | Symbols |
| A | A |
| C | C |
| D | D |
| B | B |
| Y | Y |
| E | E |
| G | G |
| H | H |
| J | J |
| 005 | Component series |
| 7X | Component series 70 … 79 (70 … 79: Unchanged installation and connection dimensions) |
| 006 | Spring return |
| With spring return | |
| OF | Without spring return with detent |
| 007 | Solenoid type |
|---|---|
| H | Standard solenoid, wet-pin |
| 008 | Direct voltage |
| G12 | Direct voltage 12 V |
| G24 | Direct voltage 24 V |
| 009 | Manual override |
| N9 | With concealed manual override |
| 010 | Electrical connection |
| Individual connection | |
| K4 | Without mating connector with connector DIN EN 175301-803 |
| C4Z | Without mating connector with connector AMP Junior-Timer |
| 011 | Seal material |
| NBR seals | |
| V | FKM seals |
| MH | Recommended for operation with HFC hydraulic fluids together with high temperatures |
| MT | Low-temperature version (only with version Without manual override) |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | Directional valve WE |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| B9 | B9 |
| B | B |
| J | J |
| JA | JA |
| T | T |
| D46 | D46 |
| H | H |
| MB | MB |
| HA | HA |
| U | U |
| Y | Y |
| E | E |
| A | A |
| V | V |
| JB | JB |
| D | D |
| F | F |
| X7 | X7 |
| C | C |
| M | M |
| Q48 | Q48 |
| A9 | A9 |
| EA | EA |
| L | L |
| HB | HB |
| G | G |
| W | W |
| EB | EB |
| G73B | G73B |
| GB | GB |
| R | R |
| G73 | G73 |
| Q | Q |
| J73 | J73 |
| GA | GA |
| UA | UA |
| 05 | Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions) |
|---|---|
| 6X | Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions) |
| 06 | Spring return |
| With spring return | |
| O | Without spring return |
| OF | Without spring return with detent |
| 07 | Solenoid type |
| E | High-power solenoid, wet (wet-pin) |
| 08 | Electrical voltages |
| G24 | Direct voltage 24 V |
| G48 | Direct voltage 48 V |
| G110 | Direct voltage 110 V |
| G... | G... |
| 09 | Manual override |
| Without manual override | |
| N | With manual override |
| 10 | Explosion protection |
| XE | Increased safety |
| 11 | Electrical connection |
| Z2 | Solenoid with terminal box and cable gland |
| 12 | Throttle insert |
| Without throttle insert | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | WE |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| J | J |
| Y | Y |
| W | W |
| D | D |
| H | H |
| JB | JB |
| J19A | J19A |
| GB | GB |
| B | B |
| G | G |
| E | E |
| U | U |
| A | A |
| B9 | B9 |
| HA | HA |
| C | C |
| 05 | Component series |
| 6X | Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions) |
| 06 | Spring return |
| With spring return |
| O | Without spring return |
| OF | Without spring return with detent |
| 07 | Solenoid type |
|---|---|
| B | High-power solenoid, wet (wet-pin) |
| 08 | Electrical voltages |
| G24 | Direct voltage 24 V |
| G110 | Direct voltage 110 V |
| G... | G... |
| W... | W... |
| 09 | Manual override |
| N | With manual override |
| Without manual override | |
| 10 | Explosion protection |
| XD | Flameproof enclosure |
| 11 | Electrical connection |
| Z2 | Individual connection; Solenoid with terminal box and adapter thread |
| 12 | Throttle insert |
| Without throttle insert | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |
| 14 | Special version |
| Without | |
| SO99 | Reinforced compression spring (symbol X36A only) |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | Directional valve |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| E | E |
| T | T |
| D | D |
| G | G |
| H | H |
| EA | EA |
| J | J |
| Y | Y |
| JB | JB |
| 05 | Component series |
| 5X | Component series 50 … 59 (50 … 59: unchanged installation and connection dimensions) |
| 06 | Spring return |
| With spring return | |
| O | Without spring return |
| OF | Without spring return with detent |
| 07 | Solenoid type |
|---|---|
| B | High-power solenoid (wet-pin) |
| 08 | Electrical voltages |
| G24 | Direct voltage 24 V |
| W120R | Alternating voltage 120 V |
| G... | G... |
| W... | W... |
| 09 | Manual override |
| N | With manual override |
| 10 | Explosion protection |
| VP1 | NEC500, NEC502, CEC Annex J and CEC Section 18 |
| 11 | Electrical connection |
| Z2 | Individual connection; Solenoid with terminal box and cable gland |
| 12 | Throttle insert |
| Without throttle insert | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |
| 01 | Version |
|---|---|
| Standard version (Maximum operating pressure 350 bar) | |
| H | High-pressure version (Maximum operating pressure 420 bar) |
| 02 | Chamber Version |
| 5 | 5-chamber version |
| 03 | Main Ports |
| 3 | 3 main ports |
| 4 | 4 main ports |
| 04 | Series |
| WE | Directional valve |
| 05 | Size |
| 10 | Size 10 |
| 06 | Symbols |
| C | C |
| D | D |
| EB | EB |
| H | H |
| J19 | J19 |
| J | J |
| P3A | P3A |
| R | R |
| X7 | X7 |
| EA | EA |
| A | A |
| E | E |
| HA | HA |
| HB | HB |
| Q | Q |
| U | U |
| X22 | X22 |
| X46B | X46B |
| X84 | X84 |
| Y | Y |
| B | B |
| E67 | E67 |
| FB | FB |
| G | G |
| JB | JB |
| RB | RB |
| W | W |
| Y11 | Y11 |
| F | F |
| J2B | J2B |
| UB | UB |
| PA | PA |
| R6 | R6 |
| U10B | U10B |
| E34 | E34 |
| JA | JA |
| P | P |
| U44 | U44 |
| J19B | J19B |
| J2 | J2 |
| A4 | A4 |
| E67A | E67A |
| LB | LB |
| J5A | J5A |
| J5B | J5B |
| GA | GA |
| X2A | X2A |
| X6 | X6 |
| L | L |
| GB | GB |
| X102 | X102 |
| FA | FA |
| UA | UA |
| G2 | G2 |
| M | M |
| B9 | B9 |
| J3A | J3A |
| G41 | G41 |
| A7 | A7 |
| G41A | G41A |
| 07 | Component Series |
| 5X | Component series 50 … 59 (50 … 59: unchanged installation and connection dimensions) |
| 08 | Spring Return |
| With spring return | |
| D | With reinforced compression spring (for quick switching off) |
| O | Without spring return |
| OF | Without spring return with detent |
| 09 | Solenoid Type |
|---|---|
| E | High-power wet-pin solenoid with detachable coil |
| 10 | Direct Voltage |
| G12 | Direct voltage 12 V |
| G24 | Direct voltage 24 V |
| G26 | Direct voltage 26 V |
| G48 | Direct voltage 48 V |
| G96 | Direct voltage 96 V |
| G110 | Direct voltage 110 V |
| G125 | Direct voltage 125 V |
| G180 | Direct voltage 180 V |
| G205 | Direct voltage 205 V |
| G220 | Direct voltage 220 V |
| 11 | Manual Override |
| Without manual override | |
| N9 | With concealed manual override (standard) |
| N8 | With concealed manual override and protective cap |
| N5 | With lockable manual override 'mushroom button' (large) |
| N6 | With manual override 'mushroom button' (large), not lockable |
| 12 | Corrosion Resistance |
| None (valve housing primed) | |
| J3 | Improved corrosion protection (240 h salt spray test according to EN ISO 9227); (only version 'K4K') |
| 13 | Electrical Connection |
| K4 | Without mating connector, with connector according to DIN EN 175301-803 |
| K4K | Without mating connector, with connector according to DIN EN 175301-803 (coil with potted-in connector base and sealing element to valve housing (IP67); with version 'J3' possible) |
| K72L | Without mating connector, 4-pole with connector M12x1, integrated interference protection circuit, status LED according to IEC 60947-5-2 |
| C4Z | Without mating connector, with AMP Junior-Timer connector |
| 14 | Spool Position Monitoring |
| Without position switch | |
| QMAG24 | Monitored spool position 'a' |
| QMBG24 | Monitored spool position 'b' |
| QM0G24 | Monitored spool position '0' |
| QSAG24W | Monitored spool position 'a' (Inductive proximity sensor type QS) |
| QSBG24W | Monitored spool position 'b' (Inductive proximity sensor type QS) |
| QS0G24W | Monitored spool position '0' (Inductive proximity sensor type QS) |
| QS0AG24W | Monitored spool position '0' and 'a' (Inductive proximity sensor type QS) |
| QS0BG24W | Monitored spool position '0' and 'b' (Inductive proximity sensor type QS) |
| QSABG24W | Monitored spool position 'a' and 'b' (Inductive proximity sensor type QS) |
| 15 | Switching Time Increase |
| Without switching time increase | |
| C | With throttle screw |
| A06 | With orifice Ø 0.6 mm [0.024 inch] |
| A08 | With orifice Ø 0.8 mm [0.031 inch] |
| A10 | With orifice Ø 1.0 mm [0.039 inch] |
| 16 | Throttle Insert |
| Without throttle insert | |
| B08 | With throttle insert: Port Throttle Ø 0.8 mm [0.031 inch] |
| B10 | With throttle insert: Port Throttle Ø 1.0 mm [0.039 inch] |
| B12 | With throttle insert: Port Throttle Ø 1.2 mm [0.047 inch] |
| H08 | With throttle insert: Port Throttle Ø 0.8 mm [0.031 inch] A |
| H10 | With throttle insert: Port Throttle Ø 1.0 mm [0.039 inch] A |
| H12 | With throttle insert: Port Throttle Ø 1.2 mm [0.047 inch] A |
| R08 | With throttle insert: Port Throttle Ø 0.8 mm [0.031 inch] B |
| R10 | With throttle insert: Port Throttle Ø 1.0 mm [0.039 inch] B |
| R12 | With throttle insert: Port Throttle Ø 1.2 mm [0.047 inch] B |
| N08 | With throttle insert: Port Throttle Ø 0.8 mm [0.031 inch] A and B |
| N10 | With throttle insert: Port Throttle Ø 1.0 mm [0.039 inch] A and B |
| N12 | With throttle insert: Port Throttle Ø 1.2 mm [0.047 inch] A and B |
| X08 | With throttle insert: Port Throttle Ø 0.8 mm [0.031 inch] T |
| X10 | With throttle insert: Port Throttle Ø 1.0 mm [0.039 inch] T |
| X12 | With throttle insert: Port Throttle Ø 1.2 mm [0.047 inch] T |
| 17 | Control Spool Play |
| Standard | |
| T06 | Minimum (to be selected in case of reduced leakage → higher level of oil cleanliness recommended) |
| T12 | Increased (to be selected in case of a hydraulic fluid/environment temperature difference > 25 K → increased internal leakage) |
| 18 | Seal Material |
| M | NBR seals |
| V | FKM seals |
| MH | Seals for HFC hydraulic fluids |
| MT | Low-temperature version |
| 19 | Approvals |
| CSA | Approval according to CSA C22.2 No. 139-10 |
| AN | Porting pattern according to ANSI B93.9 (if solenoid 'a' is energized, channel P is connected to A) |
| None |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | Directional valve WE |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| H | H |
| G | G |
| E | E |
| A | A |
| D | D |
| J | J |
| Y | Y |
| JB | JB |
| B | B |
| HA | HA |
| EA | EA |
| C | C |
| T | T |
| EB | EB |
| 05 | Component series |
| 6X | Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions) |
| 06 | Spring return |
|---|---|
| With spring return | |
| O | Without spring return |
| OF | Without spring return with detent |
| 07 | Solenoid type |
| E | High-power solenoid, wet (wet-pin) with detachable coil |
| 08 | Supply and mains voltage |
| G24 | Direct voltage 24 V |
| 09 | Manual override |
| N9 | With concealed manual override |
| 10 | Explosion protection |
| XN | Not igniting |
| 11 | Electrical connection |
| K4 | Individual connection: Solenoid without mating connector (plug-in connector according to EN 175301-803, design A) |
| 12 | Throttle insert |
| Without throttle insert (standard) | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | Directional valve WE |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| C | C |
| Y | Y |
| D | D |
| J | J |
| E | E |
| H | H |
| JB | JB |
| M | M |
| A | A |
| 05 | Component series |
| 5X | Component series 50 … 59 (50 … 59: unchanged installation and connection dimensions) |
| 06 | Spring return |
| With spring return | |
| O | Without spring return |
| 07 | Solenoid type |
| B | High-power solenoid, wet (wet-pin) |
| 08 | Electrical voltages |
|---|---|
| G12-12 | Nominal power supply 120 mA |
| G12-13 | Nominal power supply 130 mA |
| G12-19 | Nominal power supply 190 mA |
| 09 | Manual override |
| N | With manual override |
| 10 | Explosion protection |
| XH | Intrinsically safe for device group II |
| XM | Intrinsically safe for device group I |
| 11 | Electrical connection |
| CKL | Solenoid with 2 m connection line |
| Z2 | Solenoid with terminal box and cable gland |
| K20L | Solenoid with connector |
| 12 | Throttle insert |
| Without throttle insert | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |
| 01 | Main ports |
|---|---|
| 3 | 3 main ports |
| 4 | 4 main ports |
| 02 | Series |
| WE | Directional valve |
| 03 | Size |
| 6 | Size 6 |
| 04 | Symbols |
| M | M |
| D | D |
| 05 | Component series |
| 6X | Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions) |
| 06 | Spring return |
| With spring return | |
| O | Without spring return |
| OF | Without spring return with detent |
| 07 | Solenoid type |
| E | High-power solenoid, wet (wet-pin) with detachable coil |
| 08 | Electrical voltages |
| G24 | Direct voltage 24 V |
| G110 | Direct voltage 110 V |
| G... | G... |
| W... | W... |
| 09 | Manual override |
|---|---|
| N | With manual override |
| Without manual override | |
| 10 | Explosion protection |
| VE1 | Increased safety |
| 11 | Electrical connection |
| Z2 | Individual connection; Solenoid with terminal box and adapter thread |
| 12 | Throttle insert |
| Without throttle insert | |
| B08 | Throttle Ø 0.8 mm |
| B10 | Throttle Ø 1.0 mm |
| B12 | Throttle Ø 1.2 mm |
| 13 | Seal material |
| NBR seals | |
| V | FKM seals |