Technische Daten
| Typ (LSGO) | Linear sets Open, R1067 |
|---|---|
| Baureihe (A) | Super a (with misalignment compensation) |
| Wellendurchmesser (25) | 25 Shaft diameter |
|---|---|
| Dichtungen (DD) | With two seals |
| W (Minimum size in relation to Ø d.) | 11,50 | mm | |
| Schalter | 3 | ||
| Linie | 58 | mm | |
| Toleranz für H (Clamped (fastened) in relation to Ø d.) | + 8 - 16 |
||
| E2 | 40 mm ±0.15 | ||
| B1 | 40 | mm | |
| Industriekomponente (Tolerance ISO 8062-3 - DCTG 9.) | 74 | mm | |
| D | 40 | mm |
| Ventil (Tolerance ISO 8062-3 - DCTG 9.) | 9 | mm | |
| S | 5,50 | ||
| H2 (Tolerance ISO 8062-3 - DCTG 9.) | 51 | mm | |
| H | 30 | mm | |
| E1 | 60 mm ±0.15 | ||
| B (Tolerance ISO 8062-3 - DCTG 9.) | 54 | ||
| Industriekomponente | 57 | mm |
| Zulässige Umgebungstemperatur (min ... max) | -10 °C ... +80 °C | ||
| Radialspiel der Welle h6 | + 31 - 2 |
||
| FR (Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. ) | 2 | N | |
| vmax (Speeds of up to 5 m/s possible. Service life is limited by heightened wear to plastic parts. Tests have shown total travel from 50 • 105 m to 100 • 105 m without failure. ) | 3 | m/s |
| Betriebsbedingungen | Operating conditions | ||
| Losbrechkraft | 4,50 | N | |
| Maschinenschutz | 0,70 | kg | |
| amax | 150 | m/s² |