| Gewicht | .78616 lb | ||
| Versorgungsspannung | 12 to 24 vdc (ripple ?10% or less) | ||
| response time | 1 sec. or less | ||
| output note 5)specifications | accumulated pulse output | ||
| proof pressure | 1.0 mpa | ||
| indicator light | 3-digit, 7-segment led | ||
| port size (rc, npt, g) | 1/8, 1/4 | ||
| current consumption (no load) | 150 ma or less | ||
| repeatability | ?1% f.s. or less | ||
| operating fluid temperature | 0 to 50c | ||
| accumulated pulse flow rate exchange value (pulse width: 50 ms) | 0.1 l/pulse | ||
| rated flow range | 1 to 10 l/min | ||
| flow rate measurement range | 0.5 to 10.5 l/min | ||
| Baureihe | pf2a710 |
| resistance | noise resistance | ||
| Hysterese | hysteresis mode: variable (can be set from 0), window comparator mode note 6) : 3-digit fixed | ||
| status led?s | illuminates up when output is on out1: green; out2: red | ||
| accumulated flow range note 4) | 0 to 999999 l | ||
| operating pressure range | ?50 kpa to 0.5 mpa | ||
| detection type | heater type | ||
| weight note 3) | 250 g | ||
| temperature characteristics | ?3% f.s. or less (15 to 35c, based on 25c), ?5% f.s. or less (0 to 50c, based on 25c) | ||
| Linearität | ?5% f.s. or less | ||
| note 1, 2)display units | accumulated flow | ||
| minimum set unit | 0.1 l/min | ||
| set flow rate range | 0.5 to 10.5 l/min | ||
| measured fluid | air, nitrogen |
| Lagerbestand | Angebot anfordern |
|---|---|
| Teilenummer | PF2A710-N02-67-M |
| Hersteller | SMC |
| Menge | Stückpreis |
|---|---|
| 1+ | 445,62 € |