FESTO OVEM
88 Produkte
Entdecken Sie alle verfügbaren Konfigurationen für die Produktserie FESTO OVEM – Vacuum generator. Finden Sie das passende Produkt durch Filtern mit Nominal width of Laval nozzle, Vacuum type, Housing width, Pneumatic connections, Normal position of the vacuum generator und Vacuum sensor.
OVEM Typcodes
| Serie | Katalognummernformat | Beschreibung |
|---|---|---|
| OVEM | OVEM- - - - - -N | Vacuum generator |
| OVEM | OVEM- - -BN- - -N | Vacuum generator |
Typcode zur Katalognummer OVEM,
OVEM- - - - - -N
| 001 | Series |
|---|---|
| OVEM | Vacuum generator |
| 002 | Nominal width of Laval nozzle |
| 05 | 0.45 mm |
| 07 | 0.70 mm |
| 10 | 0.95 mm |
| 14 | 1.4 mm |
| 20 | 2.0 mm |
| 30 | 3.0 mm |
| 003 | Vacuum type |
| H | High vacuum |
| L | High suction rate |
| 004 | Housing width |
| B | 20 mm |
| C | 36 mm |
| 005 | Pneumatic connections |
| QS | All connections with QS fittings |
| QO | Supply/vacuum port with QS fittings, exhaust port with open silencer |
| GN | All connections with G female thread |
| GO | Supply/vacuum port with G female thread, exhaust port with open silencer |
| PL | Prepared for supply manifold, vacuum port and exhaust port with QS fittings |
| PO | Prepared for supply manifold, vacuum port with QS fittings, exhaust port with open silencer |
| 006 | Normal position of the vacuum generator |
| ON | NO, normally open (vacuum generation) |
| OE | NO, normally open (vacuum generation) with ejector pulse |
| OPE | NO, normally open (vacuum generation) with powerful ejector pulse |
| CN | NC, normally closed (no vacuum generation) |
| CE | NC, normally closed (no vacuum generation) with ejector pulse |
| CPE | NC, normally closed (no vacuum generation) with powerful ejector pulse |
| 007 | Electrical connection |
|---|---|
| N | Plug M12 (5-pin) |
| 008 | Vacuum sensor |
| Without vacuum sensor (switching input PNP) | |
| 1P | Switching output 1x PNP |
| 1PD | Switching output 1 x PNP and display |
| 1N | Switching output 1 x NPN |
| 2P | Switching output 2x PNP |
| PU | Switching output 1 x PNP + U |
| PI | Switching output 1 x PNP + I |
| 2N | Switching output 2 x NPN |
| LK | IO-Link® |
| 009 | Alternative vacuum display |
| Without | |
| H | inHg |
Typcode zur Katalognummer OVEM,
OVEM- - -BN- - -N
| 001 | Series |
|---|---|
| OVEM | Vacuum generator |
| 002 | Nominal width of Laval nozzle |
| 05 | 0.45 mm |
| 07 | 0.70 mm |
| 10 | 0.95 mm |
| 14 | 1.4 mm |
| 003 | Ejector characteristics |
| H | High vacuum/standard |
| L | High suction rate/standard |
| 004 | Housing width |
| BN | 20 mm wide, inch version |
| 005 | Pneumatic connections |
| QS | All connections with QS fittings |
| QO | Supply/vacuum port with QS fittings, exhaust port with open silencer |
| GN | All connections with G female thread |
| GO | Supply/vacuum port with G female thread, exhaust port with open silencer |
| PL | Prepared for supply manifold, vacuum port and exhaust port with QS fittings |
| PO | Prepared for supply manifold, vacuum port with QS fittings, ex- haust port with open silencer |
| 006 | Normal position of the vacuum generator |
| ON | NO, normally open (vacuum generation) |
| OE | NO, normally open (vacuum generation) with ejector pulse |
| CN | NC, normally closed (no vacuum generation) |
| CE | NC, normally closed (no vacuum generation) with ejector pulse |
| 007 | Electrical connection |
|---|---|
| N | Plug M12 (5-pin) |
| 008 | Vacuum sensor |
| Without vacuum sensor (switching input PNP) | |
| 1N | Switching output 1 x NPN |
| 1P | Switching output 1x PNP |
| 2N | Switching output 2 x NPN |
| 2P | Switching output 2x PNP |
| PI | Switching output 1 x PNP + I |
| PU | Switching output 1 x PNP + U |
| 009 | Alternative vacuum display |
| Without | |
| W | Inch H2O |
| B | Bar |