Technische Daten
| Baureihe (OVEM) | Vacuum generator |
|---|---|
| Nominal width of Laval nozzle (20) | 2.0 mm |
| Vacuum type (H) | High vacuum |
| Housing width (C) | 36 mm |
| Pneumatic connections (QO) | Supply/vacuum port with QS fittings, exhaust port with open silencer |
| Normal position of the vacuum generator (CE) | NC, normally closed (no vacuum generation) with ejector pulse |
|---|---|
| Elektrischer Anschluss (N) | Plug M12 (5-pin) |
| Vacuum sensor (LK) | IO-Link® |
| Alternative vacuum display | Without |
| Werkstoff Verschraubung | Nickel-plated brass | ||
| Werkstoff Strahldüse | Wrought aluminium alloy | ||
| Werkstoff Steckkontakte | Gold-plated brass | ||
| Werkstoff Sichtscheibe | PA | ||
| Werkstoff Schalldämpfer | Wrought aluminium alloy POM PU foam | ||
| Werkstoff Gehäuse | Wrought aluminium alloy PA-reinforced | ||
| Material filter | Fabric PA Sintered steel | ||
| Werkstoff Dichtungen | HNBR NBR | ||
| Vakuumanschluss | QS-12 | ||
| Pneumatischer Anschluss 1 | QS-10 | ||
| Manipulationssicherung | Electronic interlock | ||
| IO-Link, Device ID | 0x00003E | ||
| IO-Link, minimale Zykluszeit | 3.5 ms | ||
| IO-Link, Prozessdatenbreite IN | 2 bytes | ||
| IO-Link, Prozessdatenbreite OUT | 1 bytes | ||
| IO-Link, Communication mode | COM2 (38.4 kBaud) | ||
| IO-Link, Profil | Smart sensor profile | ||
| Protokoll | IO-Link® | ||
| Genauigkeit in ± % FS | 3 %FS | ||
| Produktgewicht | 825 g | ||
| Umgebungstemperatur | 0 °C ... 50 °C | ||
| Schutzart | IP65 | ||
| Relative Luftfeuchtigkeit | 5 - 85 % | ||
| Korrosionsbeständigkeitsklasse KBK | 2 - Moderate corrosion stress | ||
| Betriebsmedium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
| CE-Zeichen (siehe Konformitätserklärung) | To EU EMC Directive | ||
| Zulassung | RCM trademark c UL us listed (OL) | ||
| Überlastfestigkeit | Available | ||
| Spulenkennwerte | 24 V DC: low-current phase 0.3 W, high-current phase 2.55 W | ||
| Schaltausgang | 2xPNP | ||
| Max. Ausgangsstrom | 100 mA | ||
| Isolationsspannung | 50 V | ||
| Betriebsspannungsbereich DC | 20,4 V ... 27,6 V | ||
| Max. Saugvolumenstrom gegen Atmosphäre | 98 l/min | ||
| Max. vacuum | 93 % | ||
| Betriebsdruck | 2 bar ... 8 bar | ||
| Schaltzustandsanzeige | Optical | ||
| Einstellmöglichkeiten | IO-Link® Via display and keys | ||
| Darstellbare Einheit(en) | bar | ||
| Anzeigeart | 4-place alphanumeric Back-lit LCD | ||
| Verpolungsschutz | For all electrical connections | ||
| Symbol | 00992094 | ||
| Schaltelementfunktion | N/C contact N/O contact | ||
| Messgröße | Relative pressure | ||
| Konstruktiver Aufbau | Modular | ||
| Handhilfsbetätigung | Non-detenting Additionally via operating buttons | ||
| Ejektorcharakteristik | High vacuum Standard | ||
| Bauart Schalldämpfer | Open | ||
| Nennweite Lavaldüse | 2 mm |
| Werkstoff Tastenfeld | TPE-U | ||
| Material pins | Steel | ||
| Werkstoff Steckergehäuse | Nickel-plated brass | ||
| Werkstoff Schrauben | Steel | ||
| Werkstoff Regulierschraube | Steel | ||
| Material filter housing | PA-reinforced | ||
| Werkstoff Fangdüse | POM | ||
| Werkstoff-Hinweis | Contains paint-wetting impairment substances RoHS-compliant | ||
| Pneumatischer Anschluss 3 | Silencer | ||
| Befestigungsart | With through-hole Via female thread With accessories | ||
| Elektrischer Anschluss | 5-pin M12x1 Plugs | ||
| IO-Link, Datenspeicher benötigt | 500 Byte | ||
| IO-Link, Prozessdateninhalt IN | 14 bit PDV (pressure measurement value) 2 bit BDC (pressure monitoring) | ||
| IO-Link, Prozessdateninhalt OUT | 1 bit (ejector pulse IN/OUT) 1 bit (vacuum ON/OFF) | ||
| IO-Link, Port class | A | ||
| IO-Link, Funktionsklassen | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | ||
| IO-Link, Protokollversion | Device V 1.1 | ||
| Reproducibility of switching values FS | 0,6 % | ||
| Druckmessbereich | -1 bar ... 0 bar | ||
| Max. Anziehdrehmoment | 0.8 Nm with female thread 2.5 Nm with through-hole | ||
| Schutzklasse | III | ||
| Schalldruckpegel bei Nennbetriebsdruck | 62 dB(A) | ||
| Mediumstemperatur | 0 °C ... 50 °C | ||
| Hinweis zum Betriebs-/Steuermedium | Lubricated operation not possible | ||
| CE marking (see declaration of conformity) | To UK instructions for EMC | ||
| KC-Zeichen | KC-EMV | ||
| Verschmutzungsgrad | 3 | ||
| Stoßspannungsfestigkeit | 0,8 kV | ||
| Spannungsfall | ≤ 1,8 V | ||
| Reststrom | 0,1 mA | ||
| Leerlaufstrom | < 70 mA | ||
| Einschaltdauer | 100% | ||
| Air supply time at nominal operating pressure | 0,2 s | ||
| Nennbetriebsdruck | 6 bar | ||
| Operating pressure for max. vacuum | 4 bar | ||
| Einstellbereich Schwellwerte | -0,999 bar ... 0 bar | ||
| Schaltstellungsanzeige | LCD | ||
| Einstellbereich Hysterese | -0,9 bar ... 0 bar | ||
| Anzeigebereich | -0,999 bar ... 0 bar | ||
| Standard switching input | IEC 61131-2 | ||
| Ventilfunktion | Closed | ||
| Schaltfunktion | Window comparator Threshold value comparator | ||
| Messprinzip | Piezoresistive | ||
| Kurzschlussfestigkeit | yes | ||
| Integrierte Funktion | Electric ejector pulse valve Flow control Electric on-off valve Filter Air saving function, electrical Check valve Open silencer Vacuum switch | ||
| Filterfeinheit | 40 µm | ||
| Einbaulage | optional | ||
| Rastermaß | 36 mm |