| ean | 4015082788902 | ||
| product height | 75.5 mm | ||
| Product weight | .329 kg | ||
| certifications | ul (category control number qvnu2, qvnu8) ce marking ul 1077 csa-c22.2 no. 235 ul (file no. e177451) north america (ul recognized, csa certified) iec/en 60898 csa (class no. 3215-30) csa (file no. 204453) iec/en 60947-2 en45545-2 iec 61373 |
||
| 10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| rated short-circuit breaking capacity (en 60898) at 230 v | 10 ka | ||
| mounting method | top-hat rail iec/en 60715 | ||
| rated short-circuit breaking capacity (en 60898) at 400 v | 10 ka | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| frequency rating - max | 60 hz | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| number of poles (total) | 3 | ||
| rated short-circuit breaking capacity (iec 60947-2) at 230 v | 15 ka | ||
| ambient operating temperature - max | 75 °c | ||
| built-in depth | 70.5 mm | ||
| lifespan, electrical | 10000 operations | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| ambient operating temperature - min | -25 °c | ||
| selectivity class | 3 | ||
| terminal capacity (control cable) | 25 mm² (1x) | ||
| Mounting position | as required | ||
| tripping characteristic | d | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| Application | branch circuits, not as bcpd switchgear for industrial and advanced commercial applications xeffect - switchgear for industrial and advanced commercial applications |
||
| voltage type | ac | ||
| frame | 45 mm | ||
| heat dissipation capacity | 0 w | ||
| width in number of modular spacings | 3 | ||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| enclosure width | 80 mm | ||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| Degree of protection | ip40 (when fitted) ip20 ul/csa type: - ip20 (iec) |
||
| Pollution degree | 2 | ||
| connectable conductor cross section (multi-wired) - min | 1 mm² | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| admissible back-up fuse - max | 125 a gl/gg | ||
| voltage rating (ul csa 13) | 480 y/277 v ac | ||
| mounting width per pole | 17.5 mm | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| direction of incoming supply | as required | ||
| mounting width | 17.5 mm |
| product length/depth | 80 mm | ||
| product width | 54 mm | ||
| compliances | ul csa09 (with supplementary protector only) rohs conform |
||
| rated operational current for specified heat dissipation (in) | 6 a | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| current limiting class | 3 | ||
| amperage rating | 6 a | ||
| terminal capacity of screw terminals for main cable | 10 mm² (2x) | ||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| rated short-circuit breaking capacity (iec 60947-2) at 400 v | 15 ka | ||
| terminal protection | finger and hand touch safe, dguv vs3, en 50274 | ||
| special features | ambient temperature hint: a 1 °c increase results in a 0.5% linear reduction of current carrying capacity | ||
| heat dissipation per pole, current-dependent | 0 w | ||
| Features | additional equipment possible | ||
| connectable conductor cross section (solid-core) - min | 1 mm² | ||
| number of poles | three-pole | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| used with | faz miniature circuit breaker |
||
| equipment heat dissipation, current-dependent | 4.4 w | ||
| frequency rating - min | 50 hz | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| static heat dissipation, non-current-dependent | 0 w | ||
| 10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
| number of poles (protected) | 3 | ||
| terminals (top and bottom) | twin-purpose terminals | ||
| release characteristic | d | ||
| busbar material thickness | 0.8 mm - 2 mm | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| voltage rating | 240 v ac / 415 v ac | ||
| connectable conductor cross section (solid-core) - max | 25 mm² | ||
| Overvoltage category | iii | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| rated impulse withstand voltage (uimp) | 4 kv | ||
| voltage rating at dc | 60 v dc (per pole) | ||
| rated switching capacity (iec/en 60947-2) | 15 ka | ||
| connectable conductor cross section (multi-wired) - max | 25 mm² | ||
| Type | faz miniature circuit breaker |
||
| 10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
| operational switching capacity | 7.5 ka | ||
| rated operational voltage (ue) - max | 400 v | ||
| rated insulation voltage (ui) | 440 v |
| Stock | Ask for quotation |
|---|---|
| Part number | 278890 |
| Manufacturer | EATON |
| Quantity | Unit Price |
|---|---|
| 1+ | 35.24 € |
Cookies are small text files that can enhance a user's experience on websites
The law stipulates that we can store strictly necessary cookies on your device for the proper functioning of this site. For other types of cookies, we require your permission. This means necessary cookies are processed under GDPR Art. 6 (1) (f), while all other cookies, such as those in the preferences and marketing categories, are processed under GDPR Art. 6 (1) (a) GDPR.
cookies.cookies_about_type
You have the option to change or withdraw your consent at any time through the Cookie Declaration on our website.
Find more information about our identity, how to contact us, and our personal data processing practices in our Privacy Policy.