| burst impulse | 1 kv, smartwire-dt cable, according to iec/en 61131-2, level 3 1 kv, signal cable, according to iec/en 61131-2, level 3 |
||
| time delay at signal exchange - min | 10 ms | ||
| supply voltage at ac, 50 hz - max | 0 vac | ||
| supply voltage at ac, 50 hz - min | 0 vac | ||
| number of hw-interfaces (other) | 1 | ||
| connection type | swd: plug, 8-pole push in terminals, auxiliary contact external device plug swd4-8sf2-5, smartwire-dt |
||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| number of outputs (digital) | 1 | ||
| air discharge | 8 kv, according to iec 61131-2, level 3, esd | ||
| height of fall (iec/en 60068-2-32) - max | .3 m | ||
| drop and topple | 50 mm drop height, drop to iec/en 60068-2-31 | ||
| heat dissipation per pole, current-dependent pvid | 0 w | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| permitted voltage at output - min | 20.4 v | ||
| supply voltage at dc - max | 15 vdc | ||
| Cable length | ≤ 2.8 m, connection auxiliary contact | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| static heat dissipation, non-current-dependent pvs | .8 w | ||
| permitted voltage at output - max | 28.8 v | ||
| contact discharge | 4 kv, according to iec/en 61131-2, level 2, esd | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| number of auxiliary contacts | 2 | ||
| pick-up current | 125 ma (for dilm 7-9) 188 ma (for dilm 12-15) 500 ma (for dilm 17-38) |
||
| Environmental conditions | condensation: prevent with appropriate measures | ||
| 10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| functions | display of contactor switching position, status of the digital inputs 1 and 2, 1-0-a switch position for connecting the contactors to smartwire-dt contactor actuation |
||
| Pollution degree | 2 | ||
| Degree of protection | ip20 | ||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| output current | 0.5 a | ||
| addressing | address set automatically | ||
| heat dissipation capacity pdiss | 0 w | ||
| radio interference class | class a (en 55011) | ||
| product category | smartwire-dt slave | ||
| voltage type | dc | ||
| 10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| ambient operating temperature - min | -25 °c | ||
| permitted voltage at input - min | 15 v | ||
| input current at signal 1 | 3 ma | ||
| explosion safety category for gas | none | ||
| constant amplitude | 3,5 mm, 5 - 8.4 hz, according to iec/en 61131-2, vibrations | ||
| ambient storage temperature - min | 30 °c | ||
| led indicator | status indication of smartwire-dt network: green and orange led | ||
| rated operational voltage | 15 v dc (auxiliary contact) | ||
| rated operational current for specified heat dissipation (in) | 0 a | ||
| certifications | ul 508 iec/en 60947 ul en 50178 ce csa file no.: 2324643 csa class no.: 3211-07 ul file no.: e29184 iec/en 61131-2 ul category control no.: nkcr csa-c22.2 no. 14-05 iec/en 60947-4-1 csa |
||
| product width | 45 mm | ||
| product length/depth | 72 mm |
| explosion safety category for dust | none | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| relative humidity | 5 - 95 % (non-condensing, iec/en 60068-2-30) | ||
| time delay at signal exchange - max | 84 ms | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| power consumption | 3 w for dilm 7-9 (pick-up power) 4.5 w for dilm 12-15 (sealing power) 12 w for dilm 17-38 (pick-up power) 3 w for dilm 7-9 (sealing power) 4.5 w for dilm 12-15 (pick-up power) 0.5 w for dilm 17-38 (sealing power) |
||
| operating mode | address allocation via rotary switch control mode |
||
| equipment heat dissipation, current-dependent pvid | 0 w | ||
| supply voltage at ac, 60 hz - min | 0 vac | ||
| safety performance level (en iso 13849-1) | none | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| electric connection type | spring clamp connection | ||
| Mounting position | as dilm7 to dilm38 | ||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| number of inputs (digital) | 2 | ||
| sealing current | 188 ma, smartwire-dt network for dilm 12-15 21 ma, smartwire-dt network for dilm 17-38 125 ma, smartwire-dt network for dilm 7-9 |
||
| connection to smartwire-dt | yes | ||
| supply voltage at dc - min | 15 vdc | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| Shock resistance | 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 11 ms, 9 impacts | ||
| Current consumption | 40 ma, smartwire-dt network | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| data transmission type | none | ||
| Type | swd contactor modules | ||
| sil (iec 61508) | none | ||
| ambient storage temperature - max | 70 °c | ||
| Overvoltage category | ii | ||
| Protocol | other bus systems | ||
| electromagnetic fields | 3 v/m at 1.4 - 2 ghz (according to iec/en 61131-2:2008) 10 v/m at 80 - 1000 mhz (according to iec/en 61131-2:2008) 1 v/m at 2.0 - 2.7 ghz (according to iec/en 61131-2:2008) |
||
| constant acceleration | 1 g, 8.4 - 150 hz, according to iec/en 61131-2, vibrations | ||
| terminal capacity | 0.2 - 1.5 mm² (24 - 16 awg), solid 0.25 - 1.5 mm², flexible with ferrule |
||
| potential isolation | connection auxiliary contact: no | ||
| category (en 954-1) | 1 | ||
| permitted voltage at input - max | 15 v | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| supply voltage at ac, 60 hz - max | 0 vac | ||
| station | smartwire-dt slave, smartwire-dt network | ||
| Features | fieldbus connection over separate bus coupler possible | ||
| ambient operating temperature - max | 60 °c | ||
| system accessory | yes | ||
| fitted with: | own supply | ||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| 10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| radiated rfi | 10 v (iec/en 61131-2:2008, level 3) | ||
| Product weight | .037 kg | ||
| product height | 38 mm | ||
| ean | 4015081168316 |
| Stock | 3 pcs. |
|---|---|
| Part number | 118561 |
| Manufacturer | EATON |
| Quantity | Unit Price |
|---|---|
| 1+ | 44.02 € |
Cookies are small text files that can enhance a user's experience on websites
The law stipulates that we can store strictly necessary cookies on your device for the proper functioning of this site. For other types of cookies, we require your permission. This means necessary cookies are processed under GDPR Art. 6 (1) (f), while all other cookies, such as those in the preferences and marketing categories, are processed under GDPR Art. 6 (1) (a) GDPR.
cookies.cookies_about_type
You have the option to change or withdraw your consent at any time through the Cookie Declaration on our website.
Find more information about our identity, how to contact us, and our personal data processing practices in our Privacy Policy.