| ean | 4015080037729 | ||
| product height | 48 mm | ||
| Product weight | .339 kg | ||
| catalog notes | rated short-time withstand current (icw) for a time of 1 second | ||
| terminal capacity (flexible with ferrule) | 1 x (0.75 - 2.5) mm², ferrules to din 46228 2 x (0.75 - 2.5) mm², ferrules to din 46228 |
||
| rated operational current (ie) at dc-23a, 24 v | 10 a | ||
| mounting method | flush mounting | ||
| Design | 15,296 | ||
| fitted with: | black thumb grip and front plate | ||
| degree of protection (front side) | ip65 nema 12 |
||
| short-circuit current rating (high fault) | 20 a, class j, max. fuse, sccr (ul/csa) 10 ka, sccr (ul/csa) |
||
| rated operational current (ie) at dc-23a, 240 v | 5 a | ||
| actuator type | toggle | ||
| switch type | level switch | ||
| assigned motor power at 115/120 v, 60 hz, 1-phase | .5 hp | ||
| number of poles | two-pole | ||
| ambient operating temperature - min | -25 °c | ||
| rated uninterrupted current (iu) | 20 a | ||
| 10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
| product category | control switches | ||
| rated operational current (ie) at dc-23a, 48 v | 10 a | ||
| number of contacts in series at dc-23a, 24 v | 1 | ||
| assigned motor power at 460/480 v, 60 hz, 3-phase | 7.5 hp | ||
| rated operational current (ie) at ac-23a, 400 v, 415 v | 13.3 a | ||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| Overvoltage category | iii | ||
| rated operational current (ie) at dc-13, control switches l/r = 50 ms | 10 a | ||
| rated operational power at ac-23a, 500 v, 50 hz | 7.5 kw | ||
| voltage per contact pair in series | 60 v | ||
| rated operational power at ac-3, 690 v, 50 hz | 4 kw | ||
| Type | step switch | ||
| 10.2.4 resistance to ultra-violet (uv) radiation | uv resistance only in connection with protective shield. | ||
| rated operational current (ie) at ac-3, 380 v, 400 v, 415 v | 11.5 a | ||
| rated operational power at ac-3, 500 v, 50 hz | 5.5 kw | ||
| assigned motor power at 230/240 v, 60 hz, 3-phase | 3 hp | ||
| number of contact units | 11 | ||
| rated operational current (ie) at dc-21, 240 v | 1 a | ||
| rated operational current (ie) at ac-23a, 500 v | 13.3 a | ||
| rated operational power at ac-23a, 220/230 v, 50 hz | 3 kw | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| rated operational current (ie) at ac-21, 440 v | 20 a | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| assigned motor power at 575/600 v, 60 hz, 3-phase | 7.5 hp | ||
| rated operational current (ie) at ac-23a, 690 v | 7.6 a | ||
| climatic proofing | damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 |
||
| rated breaking capacity at 400/415 v (cos phi to iec 60947-3) | 110 a | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| safe isolation | 440 v ac, between the contacts, according to en 61140 | ||
| safety parameter (en iso 13849-1) | b10d values as per en iso 13849-1, table c.1 | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| rated operational power star-delta at 220/230 v, 50 hz | 5.5 kw | ||
| heat dissipation per pole, current-dependent pvid | .6 w | ||
| switching capacity (auxiliary contacts, general use) | 10a, iu, (ul/csa) | ||
| uninterrupted current | rated uninterrupted current iu is specified for max. cross-section. | ||
| assigned motor power at 200/208 v, 60 hz, 3-phase | 3 hp | ||
| rated breaking capacity at 660/690 v (cos phi to iec 60947-3) | 60 a | ||
| number of contacts in series at dc-23a, 240 v | 5 | ||
| rated operational current (ie) star-delta at ac-3, 690 v | 8.5 a | ||
| rated operational power star-delta at 690 v, 50 hz | 5.5 kw | ||
| lifespan, mechanical | 400,000 operations | ||
| number of switch positions | 11 | ||
| control circuit reliability | 1 failure per 100,000 switching operations statistically determined, at 24 v dc, 10 ma) | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| switching capacity (main contacts, general use) | 16 a, rated uninterrupted current max. (ul/csa) | ||
| rated operational current (ie) at ac-3, 500 v | 9 a | ||
| rated operational current (ie) at ac-3, 220 v, 230 v, 240 v | 11.5 a | ||
| short-circuit protection rating | 20 a gg/gl, fuse, contacts | ||
| switching capacity (auxiliary contacts, pilot duty) | a600 (ul/csa) p300 (ul/csa) |
| product length/depth | 171 mm | ||
| product width | 48 mm | ||
| certifications | ce iec/en 60204 iec/en 60947 ul category control no.: nlrv ul 60947-4-1 csa-c22.2 no. 94 ul file no.: e36332 vde 0660 csa file no.: 012528 csa class no.: 3211-05 csa csa-c22.2 no. 60947-4-1-14 ul iec/en 60947-3 |
||
| rated operational current for specified heat dissipation (in) | 20 a | ||
| 10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| rated breaking capacity at 220/230 v (cos phi to iec 60947-3) | 100 a | ||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| inscription | 1-11 | ||
| short-circuit current rating (basic rating) | 5 ka, sccr (ul/csa) 50a, max. fuse, sccr (ul/csa) |
||
| rated operational current (ie) at dc-23a, 120 v | 5 a | ||
| rated conditional short-circuit current (iq) | 6 ka | ||
| rated making capacity up to 690 v (cos phi to iec/en 60947-3) | 130 a | ||
| ambient operating temperature - max | 50 °c | ||
| rated breaking capacity at 500 v (cos phi to iec 60947-3) | 80 a | ||
| rated operational power star-delta at 380/400 v, 50 hz | 7.5 kw | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| operating frequency | 1200 operations/h | ||
| number of contacts in series at dc-23a, 48 v | 2 | ||
| rated operating voltage (ue) at ac - max | 690 v | ||
| heat dissipation capacity pdiss | 0 w | ||
| assigned motor power at 200/208 v, 60 hz, 1-phase | 1 hp | ||
| switching angle | 30 ° | ||
| Degree of protection | ip65 nema 1 nema 12 |
||
| rated operational current (ie) at ac-23a, 230 v | 13.3 a | ||
| Pollution degree | 3 | ||
| rated impulse withstand voltage (uimp) | 6000 v ac | ||
| Tightening torque | 8.8 lb-in, screw terminals 1 nm, screw terminals |
||
| rated operational current (ie) at ac-3, 660 v, 690 v | 4.9 a | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| number of contacts in series at dc-21a, 240 v | 1 | ||
| Shock resistance | 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 20 ms | ||
| ambient operating temperature (enclosed) - min | -25 °c | ||
| terminal capacity (solid/flexible with ferrule awg) | 18 - 14 | ||
| rated operational power at ac-23a, 400 v, 50 hz | 5.5 kw | ||
| rated operational current (ie) at dc-23a, 60 v | 10 a | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| ambient operating temperature (enclosed) - max | 40 °c | ||
| rated operational current (ie) star-delta at ac-3, 230 v | 20 a | ||
| screw size | m3.5, terminal screw | ||
| load rating | 1.3 x iₑ (with intermittent operation class 12, 60 % duty factor) 2 x iₑ (with intermittent operation class 12, 25 % duty factor) 1.6 x iₑ (with intermittent operation class 12, 40 % duty factor) |
||
| rated operational power at ac-3, 415 v, 50 hz | 5.5 kw | ||
| device construction | built-in device | ||
| static heat dissipation, non-current-dependent pvs | 0 w | ||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| Mounting position | as required | ||
| actuator function | maintained without 0 (off) position |
||
| rated operational power at ac-23a, 690 v, 50 hz | 5.5 kw | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| rated operational current (ie) star-delta at ac-3, 400 v | 20 a | ||
| rated operational power star-delta at 500 v, 50 hz | 7.5 kw | ||
| equipment heat dissipation, current-dependent pvid | 0 w | ||
| suitable for | branch circuits, suitable as motor disconnect, (ul/csa) front mounting |
||
| front shield size | 48x48 mm | ||
| rated operational current (ie) at dc-1, load-break switches l/r = 1 ms | 10 a | ||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| number of contacts | 22 | ||
| number of contacts in series at dc-23a, 60 v | 3 | ||
| rated short-time withstand current (icw) | 320 a, contacts, 1 second | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| number of contacts in series at dc-23a, 120 v | 3 | ||
| assigned motor power at 230/240 v, 60 hz, 1-phase | 1.5 hp | ||
| terminal capacity (solid/stranded) | 2 x (1 - 2.5) mm² 1 x (1 - 2.5) mm² |
||
| rated operational current (ie) star-delta at ac-3, 500 v | 15.6 a |
| Stock | Ask for quotation |
|---|---|
| Part number | 003772 |
| Manufacturer | EATON |
| Quantity | Unit Price |
|---|---|
| 1+ | 214.85 € |
Cookies are small text files that can enhance a user's experience on websites
The law stipulates that we can store strictly necessary cookies on your device for the proper functioning of this site. For other types of cookies, we require your permission. This means necessary cookies are processed under GDPR Art. 6 (1) (f), while all other cookies, such as those in the preferences and marketing categories, are processed under GDPR Art. 6 (1) (a) GDPR.
cookies.cookies_about_type
You have the option to change or withdraw your consent at any time through the Cookie Declaration on our website.
Find more information about our identity, how to contact us, and our personal data processing practices in our Privacy Policy.