| Ventilfunktion | 5/2-way, monostable | ||
| Baubreite | 65 mm | ||
| Pneumatischer Arbeitsanschluss | G1/4 | ||
| Betriebsdruck | 3 bar ... 10 bar | ||
| Rückstellart | Mechanical spring | ||
| Zulassung | c UL us - Recognized (OL) | ||
| CE-Zeichen (siehe Konformitätserklärung) | To EU EMC Directive To EC Machinery Directive | ||
| Zertifikat ausstellende Stelle | UL MH19482 | ||
| Dichtprinzip | Soft | ||
| Entspricht Norm | EN 60947-5-2 | ||
| Steuerart | Pilot actuated | ||
| Strömungsrichtung | Non-reversible | ||
| Messprinzip | Inductive | ||
| Reverse polarity protection sensor | For all electrical connections | ||
| Performance Level (PL) | Protection against manipulation, prevention of unexpected start-up/up to category 4, Performance Level e Reversing a movement/up to category 4, Performance Level e | ||
| Signal status display | With accessories | ||
| Switching status display sensor | LED | ||
| Suitability for vacuum | no | ||
| Schaltzeit ein | 22 ms | ||
| Valve - sensor switching time off | 11 ms | ||
| Max. positive test pulse with 0 signal | 1.000 µs | ||
| Schaltausgang | NPN | ||
| Zulässige Spannungsschwankungen | -15%/+10% | ||
| Hinweis zum Betriebs-/Steuermedium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
| Schockfestigkeit | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
| LABS-Konformität | VDMA24364-B1/B2-L | ||
| Mediumstemperatur | -5 °C ... 50 °C | ||
| Protection against direct and indirect contact | PELV Protection class to EN60950/IEC 950 | ||
| Umgebungstemperatur | -5 °C ... 50 °C | ||
| Produktgewicht | 1.138 g | ||
| Short-circuit strength sensor | Pulsed | ||
| Max. output current sensor | 200 mA | ||
| Residual ripple sensor | ± 10% | ||
| Elektrischer Anschluss | Type C To EN 175301-803 Without protective earth conductor | ||
| Befestigungsart | With through-hole | ||
| Pneumatischer Anschluss 1 | G1/4 | ||
| Pneumatischer Anschluss 3 | G1/4 | ||
| Pneumatischer Anschluss 5 | G1/4 | ||
| Werkstoff Dichtungen | FPM HNBR NBR | ||
| Werkstoff Schrauben | Galvanised steel |
| Betätigungsart | Electric | ||
| Standard nominal flow rate | 950 l/min | ||
| Operating voltage | 24V DC | ||
| Konstruktiver Aufbau | Piston gate valve | ||
| Schutzart | IP65 NEMA 4 | ||
| KC-Zeichen | KC-EMV | ||
| CE marking (see declaration of conformity) | To UK instructions for EMC To UK regulations for machines | ||
| Abluftfunktion | With flow control option | ||
| Einbaulage | optional | ||
| Handhilfsbetätigung | None | ||
| Steuerluftversorgung | Internal | ||
| Symbol | 00997332 | ||
| Überdeckung | Positive overlap | ||
| Sicherheitsfunktion | Protection against manipulation, prevention of unexpected start-up Reversing a movement | ||
| Note on forced dynamization | Switching frequency min. 1/week | ||
| Switching position sensing | Normal position via sensor | ||
| Steuerdruck | 3 bar ... 10 bar | ||
| Schaltzeit aus | 56 ms | ||
| Valve - sensor switching time on | 60 ms | ||
| Einschaltdauer | 100% | ||
| Max. negative test pulse with 1 signal | 800 µs | ||
| Spulenkennwerte | 24 V DC: 1.8 W | ||
| Betriebsmedium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
| Schwingfestigkeit | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
| Korrosionsbeständigkeitsklasse KBK | 0 - No corrosion stress | ||
| Max. magnetic interference field | 60 mT | ||
| Schalldruckpegel | 85 dB(A) | ||
| Steuermedium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
| Nominal altitude of use | 1000 m in accordance with VDE 0580 | ||
| Operating voltage range, DC sensor | 10 V ... 30 V | ||
| Idle current sensor | ≤ 10 mA | ||
| Max. switching frequency sensor | 5.000 Hz | ||
| Voltage drop sensor | ≤ 2 V | ||
| Sensor connection | Plug 3-pin M8x1 | ||
| Pressure gauge connection | G1/4 | ||
| Pneumatischer Anschluss 2 | G1/4 | ||
| Pneumatischer Anschluss 4 | G1/4 | ||
| Werkstoff-Hinweis | RoHS-compliant | ||
| Werkstoff Gehäuse | Die-cast aluminium PA | ||
| Schaltelementfunktion | N/C contact |