| Material housing | PA-reinforced PC | ||
| Type of mounting | On interlinking block | ||
| Max. cable length | 500 m | ||
| Data format | 15 bits + prefix Scalable to 15 bits | ||
| Min. available sensor voltage | 20.7 V at 20 mA | ||
| Max. short circuit current | 22 mA | ||
| Max. load | 750 Ohm | ||
| Ambient temperature | -5 °C ... 50 °C | ||
| Relative air humidity | 95 % Non-condensing | ||
| Corrosion resistance class CRC | 1 - Low corrosion stress (when installed) | ||
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
| Isolation channel - channel | no | ||
| Power failure bridging | 10 ms | ||
| Basic error limit at 25 °C | ±0.1% | ||
| Intern power consumption nominal operating voltage | Typ. 170 mA | ||
| Fuse protection (short circuit) | Internal electronic fuse per channel | ||
| LED display | 1 Group diagnostics 4 channel diagnostics 4 Channel status | ||
| Reverse polarity protection | For all electrical connections | ||
| Number of selectable analogue inputs/outputs | 4 | ||
| Dimensions (W x L x H) | (incl. interlinking block and connection technology) 50 x 107 x 70 mm |
| Note on materials | RoHS-compliant | ||
| Sensor type | 0 - 20 mA 4 - 20 mA 4 - 20 mA with HART | ||
| Protocol | HART | ||
| analog input | 0 - 20 mA 4 - 20 mA 4 - 20 mA with HART | ||
| Max. open circuit voltage | 28,8 V | ||
| Max. input resistance | 300 Ohm | ||
| Product weight | 77,4 g | ||
| Degree of protection | Dependent on the manifold block | ||
| Storage temperature | -20 °C ... 70 °C | ||
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
| CE mark (see declaration of conformity) | To EU EMC Directive | ||
| Isolation channel - internal bus | yes | ||
| Nominal operating voltage DC | 24 V | ||
| Operating error limit related to the ambient temperature range | ±0.3% | ||
| Operational voltage range DC | 18 V ... 30 V | ||
| Repetition accuracy | 0.05% at 25ºC | ||
| Operator controls | DIL switch | ||
| Diagnosis | Wire break per channel Limit value violation per channel Short circuit/overload per channel Parameterisation error Overflow/underflow Limit value violation as per NE43 per channel | ||
| Grid dimension | 50 mm | ||
| Parameterisation | Data format Fail-safe per channel Forcing per channel Limit monitoring per channel Idle mode per channel Measured value smoothing Signal range per channel Overflow/underflow monitoring Monitoring according to NE43 inputs Wire break monitoring per channel Number of HART repetitions Wire break per channel Limit value violation as per NE43 per channel Limit value violation per channel HART variables Hysteresis for critical limits Short circuit/overload per channel Parameterisation error Overflow/underflow Behaviour after short circuit/overload |
| Stock | Ask for quotation |
|---|---|
| Part number | 8059847 |
| Manufacturer | FESTO |
| Quantity | Unit Price |
|---|---|
| 1+ | 700.68 € |