| Shock resistance | mechanical, according to iec/en 60068-2-27 continuous according to iec/en 60068-2-29 |
||
| Environmental conditions | harmful gasses - so2: 10 ppm (relative humidity < 75%, no condensation) harmful gasses - h2s: 1 ppm (relative humidity < 75%, no condensation) |
||
| 10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
| Type | xi/on slice card base module | ||
| explosion safety category for dust | none | ||
| sil (iec 61508) | none | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| input voltage at ac 60 hz - max | 0 v | ||
| relative humidity | 5 - 95 % (indoor, level rh-2, non-condensing for storage at 45°c) | ||
| electromagnetic fields | according to iec en 61100-4-2 | ||
| connection type | spring-loaded/screw terminal, connection design in top direction | ||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| input voltage at ac 60 hz - min | 0 v | ||
| heat dissipation capacity pdiss | 0 w | ||
| terminal capacity | 0.5 - 1.5 mm², flexible without ferrule, h07v-k 0.5 - 1.5 mm², with ferrules without plastic collar according to din 46228-1 (ferrules crimped gas-tight) 0.5 - 1.5 mm², with ferrules with plastic collar according to din 46228-1 (ferrules crimped gas-tight) 0.5 - 2.5 mm², solid, h07v-u |
||
| potential isolation | through optocoupler: yes | ||
| safety performance level (en iso 13849-1) | none | ||
| heat dissipation per pole, current-dependent pvid | 0 w | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| output voltage at ac 60 hz - max | 0 v | ||
| voltage dips | according to en 61131-2 (voltage fluctuations/voltage dips) | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| emitted interference | 230 - 1000 mhz (radiated, high frequency, according to en 55016-2-3) 30 - 230 mhz (radiated, high frequency, according to en 55016-2-3) |
||
| output voltage at ac 60 hz - min | 0 v | ||
| explosion safety category for gas | none | ||
| input voltage at dc - max | 0 v | ||
| output current at ac, 60 hz - max | 0 a | ||
| Vibration resistance | according to iec/en 60068-2-6 | ||
| surge rating | according to iec/en 61000-4-5 level 4 | ||
| stripping length (main cable) | 8 mm | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| number of slots | 1 | ||
| mounting method | rail mounting possible | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| 10.11 short-circuit rating | is the panel builder's responsibility. | ||
| radiated rfi | iec/en 61100-4-6 | ||
| certifications | iec/en 6113-2 rated data for terminations according to iec/en 60947-7-1 ul file no.: e205091 ul report applies to both us and canada certified by ul for use in canada csa-c22.2 no. 142 iec/en 61000-6-4 ul category control no.: nraq, nraq7 ul recognized csa class no.: 2252-01, 2252-81 ce iec/en 61000-6-2 iec/en 61131-2 ul 508 ce, cul |
||
| product width | 12.6 mm | ||
| product length/depth | 117.6 mm |
| input voltage at ac 50 hz - min | 0 v | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| burst impulse | according to iec/en 61000-4-4 | ||
| output current at dc - max | 0 a | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| output current at ac, 50 hz - max | 0 a | ||
| Degree of protection | ip20 | ||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| input current at ac - max | 0 a | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| number of connection levels | 3 | ||
| air discharge | air/contact discharge according to iec/en 61000-4-2 | ||
| equipment heat dissipation, current-dependent pvid | 0 w | ||
| output voltage at dc - max | 0 v | ||
| drop and topple | according to iec 60068-2-31, free fall according to iec 60068-2-32 | ||
| voltage type | dc | ||
| 10.3 degree of protection of assemblies | meets the product standard's requirements. | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| output voltage at dc - min | 0 v | ||
| used with | xn-pf-24vdc-d xn-pf-120/230vac-d xn-br-24vdc-d |
||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| ambient operating temperature - min | 0 °c | ||
| static heat dissipation, non-current-dependent pvs | 0 w | ||
| input current at dc - max | 0 a | ||
| ambient operating temperature - max | 55 °c | ||
| output voltage at ac 50 hz - min | 0 v | ||
| system accessory | yes | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| fitted with: | pluggable modules, central modules power supply pluggable modules, others |
||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| output voltage at ac 50 hz - max | 0 v | ||
| input voltage at dc - min | 0 v | ||
| gauge pin | a1 (according to iec/en 60947-1) | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. | ||
| input voltage at ac 50 hz - max | 0 v | ||
| rated operational current for specified heat dissipation (in) | 0 a | ||
| catalog notes | base module for the gateway supply (with xn‑br-24v dc-d) | ||
| Product weight | .031 kg | ||
| product height | 49.9 mm | ||
| ean | 7640130120952 |