| Pollution degree | 3 | ||
| Insulation voltage | 2.000 V | ||
| Setting options | Permanently set | ||
| Material electrical connection | Tin-plated | ||
| Material housing | PA-reinforced POM Steel VMQ (silicone) | ||
| Mounting position | optional | ||
| Material cable sheath | PVC | ||
| Electrical connection 1, connector system | Open end | ||
| Utilisation category - resistive load | AC-12 DC-12 | ||
| Operational voltage range DC | 12 V ... 250 V | ||
| Min. load current | 100 mA | ||
| Switch-off point | ≤ 0,1 bar | ||
| Switching element function | Changeover switch | ||
| Switching output | Contacting | ||
| Media temperature | 0 °C ... 60 °C | ||
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
| Operating pressure | -0,95 bar ... 0 bar | ||
| Measured variable | Relative pressure | ||
| CE mark (see declaration of conformity) | To EU Low Voltage Directive | ||
| Symbol | 00995409 |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
| Degree of protection | IP67 | ||
| Material membrane | CR | ||
| Material switch contact | Silver | ||
| Pneumatic connection | G1/8 | ||
| Type of mounting | On 2n mounting frame With through-hole Either: | ||
| Cable length | 0,5 m | ||
| Electrical connection | 3 connector leads | ||
| Utilisation category - inductive load | AC-14 DC-13 | ||
| Operational voltage range AC | 12 V ... 250 V | ||
| Max. switching frequency | 1 Hz | ||
| Switch-on point | -0,25 bar | ||
| Switching function | Threshold value with fixed hysteresis | ||
| Ambient temperature | 0 °C ... 60 °C | ||
| Note on operating and pilot medium | Lubricated operation possible | ||
| Max. overload pressure | 1 bar | ||
| Measurement method | Pneumatic/electric pressure transducer | ||
| CE marking (see declaration of conformity) | To UK regulations for electrical equipment | ||
| Approval | CCC | ||
| Conforms to standard | EN 60947-5-1 |