| Material housing | PA-reinforced | ||
| LED display, product-specific | M: Modify, parameterisation PL: Load supply PS: Electronics supply, sensor supply SF: System fault | ||
| Protocol | EtherCAT | ||
| Max. address volume, outputs | 128 Byte | ||
| Ambient temperature | -5 °C ... 50 °C | ||
| Storage temperature | -20 °C ... 70 °C | ||
| Nominal operating voltage DC | 24 V | ||
| Operational voltage range DC | 18 V ... 30 V | ||
| Operator controls | DIL switch | ||
| Configuration support | ESI file | ||
| Device-specific diagnostics | Channel-oriented and module-oriented diagnostics Undervoltage of modules Diagnostic memory | ||
| Dimensions (W x L x H) | (incl. interlinking block) 50 x 107 x 50 mm |
| Note on materials | RoHS-compliant | ||
| LED display, bus-specific | Error: Communication error LA X1: network active port 1 LA X2: Network active port 2 Run: Communication status | ||
| Max. address volume, inputs | 128 Byte | ||
| Product weight | 125 g | ||
| Degree of protection | IP65 IP67 | ||
| Corrosion resistance class CRC | 1 - Low corrosion stress | ||
| Intern power consumption nominal operating voltage | Typically 100 mA | ||
| Baud rate | 100 Mbit/s | ||
| Additional functions | Acyclic data access via fieldbus Diagnostics object Emergency message Compatibility mode for the FB38 Modular device profile (MDP) System status can be mapped using process data Variable PDO mapping Additional diagnostic interface for operator units | ||
| Parameterisation | Diagnostic behaviour Fail-safe response Forcing of channels Signal setup System parameter | ||
| Field bus interface | 2x socket, M12x1, 4-pin, D-coded |