| Weight | .90389 lb | ||
| weight note 3) | 410 g | ||
| current consumption (no load) | 20 ma or less | ||
| output note 2)specifications | analog output | ||
| repeatability note 1) | ?3% f.s. or less | ||
| operating fluid temperature | 0 to 50c | ||
| operating pressure range | 0 to 1 mpa | ||
| detection type | karman vortex | ||
| model | pf2w504 |
| port size (rc, npt, g) | 3/8 | ||
| resistance | noise resistance | ||
| power supply voltage | 12 to 24 vdc (ripple ?10% or less) | ||
| temperature characteristics | ?2% f.s. or less (15 to 35c based on 25c), ?3% f.s. or less (0 to 50c, based on 25c) | ||
| linearity note 1) | ?5% f.s. or less | ||
| withstand pressure | 1.5 mpa | ||
| rated flow range | 0.5 to 4 l/min | ||
| measured fluid | water |
| Stock | Ask for quotation |
|---|---|
| Part number | PF2W504-N03N |
| Manufacturer | SMC |
| Quantity | Unit Price |
|---|---|
| 1+ | 347.25 € |