| Material housing | POM | ||
| Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
| LABS (PWIS) conformity | VDMA24364-B2-L | ||
| CE mark (see declaration of conformity) | To EU EMC Directive | ||
| Degree of protection | IP40 | ||
| Cable length | 2,5 m | ||
| Note on input current | Linear rise 0.09-0.44 mA with a trigger signal of 3-15 V 0.44-15.44 mA with a trigger signal of 15-30 V | ||
| Duty cycle | 100% Observe the notes on operating the solenoid valves. | ||
| Note on operation | Fixed power supply must be able to supply at least 1.85 A without voltage drop. | ||
| Operational voltage range DC | 12 V ... 53 V | ||
| Product weight | 98 g | ||
| Type of mounting | With through-hole With H-rail Either: | ||
| Approval | RCM trademark |
| Material cable sheath | PVC | ||
| Note on materials | RoHS-compliant | ||
| KC mark | KC-EMV | ||
| Ambient temperature | -5 °C ... 50 °C | ||
| Cable characteristic | For static applications | ||
| Input resistance | 34 kOhm | ||
| Trigger signal voltage range DC | 3 V ... 30 V | ||
| Information on power consumption | Low-current phase 2.8 W, high-current phase 17.1 W, per channel | ||
| Reverse polarity protection | For operating voltage | ||
| Electrical connection | 2-pin/2-pin/4-wire Straight socket/straight socket/cable | ||
| Mounting position | optional | ||
| Additional functions | Spark arresting Holding current reduction with energy recovery Safety shut-off |