| Mounting position | optional | ||
| Ambient temperature | -10 °C ... 60 °C | ||
| Note on materials | RoHS-compliant | ||
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
| Standard nominal flow rate | 3.800 l/min | ||
| C value | 17,3 l/sbar | ||
| Valve function | 3/2 double solenoid | ||
| Manual override | None | ||
| Sealing principle | Soft | ||
| Design | Piston gate valve | ||
| Material seals | NBR | ||
| Pneumatic connection, port 3 | G1/4 | ||
| Pneumatic connection, port 1 | G3/4 | ||
| Flow direction | Non-reversible |
| Type of mounting | In-line installation With accessories | ||
| Media temperature | -10 °C ... 60 °C | ||
| Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases | ||
| b value | 0,42 | ||
| Operating pressure | 0 bar ... 16 bar | ||
| Symbol | 00995571 | ||
| Exhaust-air function | Without flow control option | ||
| Type of actuation | Manual | ||
| Material housing | Die-cast aluminium | ||
| Air purity class at output | Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases | ||
| Pneumatic connection, port 2 | G3/4 | ||
| Product weight | 511 g |