1 Products
Specifications
- All-purpose high pressure motor
- Size 28 … 1000
- Nominal pressure up to 400 bar
- Maximum pressure up 450 bar
- Open and closed circuits
- Metric version
Discover all the available configurations for the REXROTH A6V product series Bent-axis design, variable. Find the right product by filtering with and Series.
A6V Type Codes
| Series | Catalog Number Format | Description |
|---|---|---|
| A6V | A6V-M- - - - - -0- - -65- -W-V-0- - - - - - | Bent-axis design, variable |
Typecode for Catalog Number A6V,
A6V-M- - - - - -0- - -65- -W-V-0- - - - - -
| 01 | Series |
|---|---|
| A6V | Bent-axis design, variable |
| 02 | Operating mode |
| M | Motor |
| 03 | Size |
| 028 | Geometric displacement |
| 055 | Geometric displacement |
| 080 | Geometric displacement |
| 107 | Geometric displacement |
| 140 | Geometric displacement |
| 160 | Geometric displacement |
| 200 | Geometric displacement |
| 04 | Control device |
| HP1 | Proportional control, positive control ΔpSt = 10 bar |
| HP2 | Proportional control, positive control ΔpSt = 25 bar |
| HP5 | Proportional control, negative control ΔpSt = 10 bar |
| HP6 | Proportional control, negative control ΔpSt = 25 bar |
| EP1 | Electric positive control U = 12 V |
| EP2 | Electric positive control U = 24 V |
| EP5 | Electric negative control U = 12 V |
| EP6 | Electric negative control U = 24 V |
| HZ5 | Two-point control, hydraulic negative control |
| HZ7 | Two-point control, hydraulic negative control |
| EZ5 | Two-point control, negative control U = 12 V |
| EZ6 | Two-point control, negative control U = 24 V |
| EZ7 | Two-point control, negative control U = 12 V |
| EZ8 | Two-point control, negative control U = 24 V |
| HA1 | Automatic control with minimum pressure increase Δp ≤ approx. 10 bar |
| HA2 | High-pressure related, positive control with pressure increase Δp = 100 bar |
| DA0 | Speed related, negative control pSt / pHD = 5/100 hydraulic travel direction valve |
| DA1 | Speed related, negative control electr. travel direction valve + electr. Vg max override U = 12 V |
| DA2 | Speed related, negative control electr. travel direction valve + electr. Vg max override U = 24 V |
| 05 | Pressure control/override |
| 00 | Without pressure control/override |
| D1 | Pressure control fixed setting, only for HP5, HP6, EP5 and EP6 |
| T3 | Override of the HA1 and HA2 controls hydraulic remote control, proportional |
| U1 | Override of the HA1 and HA2 controls electric, two-point U = 12 V |
| U2 | Override of the HA1 and HA2 controls electric, two-point U = 24 V |
| R1 | Override of the HA1 and HA2 controls electric and travel direction valve, electric U = 12 V |
| R2 | Override of the HA1 and HA2 controls electric and travel direction valve, electric U = 24 V |
| 06 | Connector for solenoids |
| 0 | Without connector (without solenoid, only for hydraulic control) |
| P | DEUTSCH - molded connector, 2-pin, without suppressor diode |
| 07 | Swivel angle sensor |
| 0 | Without |
| N | Neutral position switch |
| 08 | Additional function |
| 0 | Without additional function |
| 09 | Stroking time damping |
| 0 | Without damping (standard with HP and EP) |
| 1 | Damping HP, EP, HP5,6D. and EP5,6D., HZ, EZ, HA with BVD/BVE counterbalance valves |
| 4 | One-sided in inlet to large stroking chamber (HA) |
| 7 | One-sided in outlet from large stroking chamber (DA) |
| 10 | Setting range for displacement |
| A | short (0-adjustable) |
| B | moderate |
| C | long |
| D | extra long |
| E | short short (0-adjustable) |
| F | moderate |
| G | long |
| H | extra long |
| J | medium short (0-adjustable) |
| K | moderate |
| L | long |
| M | extra long |
| 11 | Series |
|---|---|
| 65 | Series 6, index 5 |
| 12 | Version of port and fastening threads |
| M | Metric ports based on ISO 6149 with O-ring seal, metric fastening threads according to DIN 13 |
| N | Metric ports based on DIN 3852 with profile sealing ring, metric fastening thread according to DIN 13 |
| 13 | Direction of rotation |
| W | Viewed on drive shaft, bidirectional |
| 14 | Seal Material |
| V | FKM (fluorocarbon rubber) |
| 15 | Drive shaft bearing |
| 0 | Standard bearing |
| 16 | Mounting flange |
| L4 | ISO 3019-2 100-4 |
| M4 | ISO 3019-2 125-4 |
| N4 | ISO 3019-2 140-4 |
| P4 | ISO 3019-2 160-4 |
| R4 | ISO 3019-2 180-4 |
| S4 | ISO 3019-2 200-4 |
| 17 | Drive shaft |
| S7 | Splined shaft ANSI B92.1a 1 1/4 in 14T 12/24 DP |
| T1 | Splined shaft ANSI B92.1a 1 3/4 in 13T 8/16 DP |
| T2 | Splined shaft ANSI B92.1a 2 in 15T 8/16 DP |
| Z5 | Splined shaft DIN 5480 W25×1.25×18×9g |
| Z6 | Splined shaft DIN 5480 W30×2×14×9g |
| Z8 | Splined shaft DIN 5480 W35×2×16×9g |
| Z9 | Splined shaft DIN 5480 W40×2×18×9g |
| A1 | Splined shaft DIN 5480 W45×2×21×9g |
| A2 | Splined shaft DIN 5480 W50×2×24×9g |
| 18 | Working port |
| 1 | SAE working ports A and B at rear |
| 2 | SAE working ports A and B at side, opposite |
| 4 | SAE working port A and B at rear, with lateral measuring ports |
| 6 | SAE working port A and B at bottom, with integrated counterbalance valve |
| 7 | Port plate for mounting a counterbalance valve, with 1-stage pressure relief valve (pilot operated) BVD20 |
| 8 | Port plate for mounting a counterbalance valve, with 1-stage pressure relief valve (pilot operated) BVD25 |
| 8 | Port plate for mounting a counterbalance valve, with 1-stage pressure relief valve (direct operated) BVE25 |
| 9 | Port plate for mounting a counterbalance valve, with 1-stage pressure relief valve (direct operated) BVD/BVE 32 |
| 19 | Valve |
| 0 | Without valve |
| Y | With integrated brake release valve (only with port plate 6) |
| W | With BVD/BVE counterbalance valves mounted |
| A | With flushing and boost-pressure valve mounted, flushing flow qv = 3.5 l/min |
| B | With flushing and boost-pressure valve mounted, flushing flow qv = 5 l/min |
| C | With flushing and boost-pressure valve mounted, flushing flow qv = 8 l/min |
| D | With flushing and boost-pressure valve mounted, flushing flow qv = 10 l/min |
| F | With flushing and boost-pressure valve mounted, flushing flow qv = 14 l/min |
| G | With flushing and boost-pressure valve mounted, flushing flow qv = 15 l/min |
| H | With flushing and boost-pressure valve mounted, flushing flow qv = 16 l/min |
| I | With flushing and boost-pressure valve mounted, flushing flow qv = 18 l/min |
| J | With flushing and boost-pressure valve mounted, flushing flow qv = 21 l/min |
| K | With flushing and boost-pressure valve mounted, flushing flow qv = 27 l/min |
| L | With flushing and boost-pressure valve mounted, flushing flow qv = 31 l/min |
| M | With flushing and boost-pressure valve mounted, flushing flow qv = 37 l/min |
| 20 | Speed sensor |
| 0 | Without speed sensor |
| W | Prepared for sensor DSA/20 and DST |
| C | DSA/20 speed sensor mounted |
| E | DST speed sensor mounted |
| 21 | Standard/special version |
| 0 | Standard version |
| Y | Standard version with installation variants, e.g. T ports open and closed contrary to standard |
| S | Special version |