| Pollution degree | 3 | ||
| Corrosion resistance class CRC | 1 - Low corrosion stress | ||
| Insulation voltage | 500 V | ||
| Setting options | IO-Link® Potentiometer Teach-in | ||
| Ready status indication | Green LED | ||
| Product weight | 10 g | ||
| Tightening torque | 0,8 Nm | ||
| Material electrical contact | Gold-plated brass | ||
| Electrical connection 1, type of mounting | Screw-type lock | ||
| Electrical connection 1, connector system | M8x1, A-coded, to EN 61076-2-104 | ||
| Reverse polarity protection | For all electrical connections | ||
| Residual ripple | 10 % | ||
| IO-Link, Data storage required | 2.000 Byte | ||
| IO-Link, Process data content IN | 1 bit (signal quality indicator) 16 bit PDV (distance) 2 bit SSC (switching signal) | ||
| IO-Link, Process data content OUT | 1 bit (emitter disable) 1 bit (Hold) | ||
| IO-Link, Port class | A | ||
| IO-Link, communication mode | COM2 (38.4 kBaud) | ||
| IO-Link, Profile | Smart sensor profile | ||
| Protocol | IO-Link® | ||
| Timer function | Via IO-Link® | ||
| Voltage drop | 0 V ... 1,5 V | ||
| Max. switching frequency | 270 Hz | ||
| Switching output | Push-pull | ||
| Repetition accuracy | 0,5 mm | ||
| Reference material | Standard white 90%, 100x100 mm | ||
| Displacement measuring range | 40 mm ... 100 mm | ||
| Max. light spot | 3 mm at a sensing range of 100 mm | ||
| Measurement method | Distance sensor | ||
| Note on materials | Contains paint-wetting impairment substances RoHS-compliant | ||
| CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
| Symbol | 00995956 | ||
| Design | Block design |
| Laser safety class | 1 | ||
| Immunity to surge | 1 kV | ||
| Degree of protection | IP65 IP67 IP69K | ||
| Switching status indication | Yellow LED | ||
| Material housing | PC PMMA | ||
| Mounting position | optional | ||
| Type of mounting | Via through-hole for M3 screw | ||
| Electrical connection 1, connection pattern | 00991155 | ||
| Electrical connection 1, number of connections/cores | 3 | ||
| Electrical connection 1, connection type | Plugs | ||
| No-load supply current | 25 mA | ||
| Operational voltage range DC | 10 V ... 30 V | ||
| IO-Link, Min. cycle time | 3 ms | ||
| IO-Link, Process data length IN | 3 bytes | ||
| IO-Link, Process data length OUT | 2 bit | ||
| IO-Link, SIO-Mode support | Yes | ||
| IO-Link, Function classes | Process data variable (PDV) Identification Diagnostics Teach channel Switching signal channel (SSC) | ||
| IO-Link, Protocol version | Device V 1.1 | ||
| Short circuit current rating | Pulsed | ||
| Linearity error in ± %FS | 0,75 % | ||
| Max. output current | 100 mA | ||
| Switching element function | Switchable PNP, light switching NPN, dark switching | ||
| Temperature cooefficient | 0,03 %/K | ||
| Displacement resolution | 0,1 mm | ||
| Ambient temperature | 10 °C ... 60 °C | ||
| Min. object diameter | 4 mm | ||
| Type of light | Laser Red | ||
| Measuring principle | Optoelectronic | ||
| Certificate issuing authority | UL E232949 | ||
| Approval | RCM trademark c UL us listed (OL) | ||
| Conforms to standard | EN 60947-5-2 |